Australian Combined Loading — AS 4100 Clause 8.4

Quick access: [[Australian Steel Grades|/reference/australian-steel-grades/]] | [[Australian Steel Properties|/reference/australian-steel-properties/]] | [[Australian Beam Sizes|/reference/au-beam-sizes/]] | [[Australian Bolt Capacity|/reference/australian-bolt-capacity/]] | [[AS 4100 Beam Design|/reference/as4100-beam-design-example/]] | [[All Australian References|/reference/]]


Reference for combined axial compression and bending design per AS 4100:2020 Clause 8.4. Covers interaction formulas, moment amplification (δb), and biaxial bending checks.

Interaction Formula — AS 4100 Clause 8.4.2

Mx/φMbx + My/φMby ≤ 1.0**

And separately: N/φNc + Mx/φMsx + My*/φMsy ≤ 1.0**

Where:

Moment Amplification — Clause 8.4.3

M* = δb × M*b + δs × M*s

Where:

δb values for common cases:

N*/φNoc Cm=1.0 Cm=0.85 Cm=0.6
0.1 1.11 0.95 0.67
0.2 1.25 1.06 0.75
0.3 1.43 1.21 0.86
0.4 1.67 1.42 1.00
0.5 2.00 1.70 1.20

Biaxial Bending — Clause 8.4.5

For RHS/SHS and symmetric sections: (Mx*/φMsx)^1.4 + (My*/φMsy)^1.4 ≤ 1.0

For I-sections (strong axis bending dominates): Mx*/φMsx + (My*/φMsy)^2 ≤ 1.0 (when N* ≤ φNc)

Simplified (conservative): Mx*/φMsx + My*/φMsy ≤ 1.0

Worked Example

Problem: 310UC137 (φNc=3,200 kN, φMsx=620 kNm). N*=1,200 kN, M*x=280 kNm (including δb=1.15). φNoc=8,000 kN.

Solution:

  1. N*/φNc = 1,200/3,200 = 0.38 < 1.0 OK
  2. Check interaction: N*/φNc + Mx*/φMsx = 0.38 + 280/620 = 0.38 + 0.45 = 0.83 ≤ 1.0 OK
  3. Check second formula: 1,200/3,200 + 280/620 = 0.83 ≤ 1.0 OK
  4. Moment amplification OK: δb = Cm/(1−1200/8000) = Cm/0.85

Design Resources

FAQ

When is moment amplification important? When N*/φNoc > 0.3, amplification exceeds 1.4. At N*/φNoc = 0.5, amplification is 2.0. Critical for slender columns.

How is Cm determined? Cm = 0.6 - 0.4β for linear moment gradient (β = end moment ratio). Cm = 1.0 for transverse loading between supports.

What is the biaxial bending exponent? 1.4 for RHS/SHS and symmetrical sections, 2.0 for I-section weak axis, per Clause 8.4.5.


Educational Use Only — This reference is for educational and preliminary design purposes only. All structural designs must be independently verified by a licensed Professional Engineer (PE) or Structural Engineer (SE) in accordance with AS 4100:2020 and all applicable Australian Standards. Results are not for construction.