Column Splice Design Worked Example — W12x65 Bearing-Type Bolts per AISC 360-22

Complete step-by-step column splice design for a W12x65 column in a 10-story braced frame. Bearing-type splice with bolted flange plates and web plates. All intermediate calculations shown with actual numbers and AISC 360-22 code references.

Problem Statement

PRELIMINARY — NOT FOR CONSTRUCTION. All results are for educational and reference use only. Must be independently verified by a licensed Professional Engineer (PE) or Structural Engineer (SE) before use in any project.

A W12x65 interior gravity column is spliced between the 4th and 5th floors of a 10-story office building with braced frames. The splice is located 4 ft above the 4th floor finished floor level. The column is ASTM A992 steel (Fy = 50 ksi, Fu = 65 ksi).

Section Properties — W12x65:

Property Value Units
d 12.1 in.
bf 12.0 in.
tf 0.605 in.
tw 0.390 in.
kdes 1.11 in.
A 19.1 in.²
Ix 533 in.⁴
Iy 174 in.⁴
rx 5.28 in.
ry 3.02 in.
T (flange-to-flange) 12.1 in.

Design Forces at Splice (factored, LRFD):

Minimum Axial per AISC B3.6: The column available compressive strength is phi Pn = 719 kips (from column design). Minimum splice design force = 0.50 × 719 = 360 kips. Since P_u = 420 kips > 360 kips, the design is governed by the actual demand. Use P_u = 420 kips.


Step 1: Flange Force Calculation

For a column splice, the axial force plus moment-induced flange forces must be transferred. The flange force for each flange:

P_f = P_u / 2 + M_uy / (d_eff between flanges)

Where the effective lever arm between flange centroids is:

d_eff = d - tf = 12.1 - 0.605 = 11.50 in.

Moment contribution to flange force:

P_f_moment = M_uy × 12 / d_eff = 45 × 12 / 11.50 = 540 / 11.50 = 47.0 kips

Axial contribution per flange:

P_f_axial = P_u / 2 = 420 / 2 = 210 kips

Total flange force (compression side = additive, tension side = subtractive):

P_f_compression = 210 + 47.0 = 257.0 kips (governs for bearing splice — compression flange carries more)
P_f_tension = 210 - 47.0 = 163.0 kips

Since this is a bearing splice, the compression flange force is primarily transferred through mill-to-bear contact between column ends. The splice plates provide alignment and resist the tension flange force. For a non-bearing splice (conservative approach used here), design the flange plates for the full compression flange force P_f = 257 kips.


Step 2: Flange Splice Plate Sizing

Use flange splice plates on the outside faces of both flanges: PL 12 × 3/8 in., ASTM A572 Gr 50 (Fy = 50 ksi, Fu = 65 ksi).

Outer plate properties (per plate):

Inner splice plates (between column flanges): 2 PL 12 × 3/8 in. (one on each side of web, designed similarly — omitted for brevity but included in the summary).


Step 3: Bolt Configuration

Bolt layout on each flange face: 2 vertical rows of 3 bolts (6 bolts per flange face, 12 total per flange pair including inner and outer plates). Bolts: 3/4 in. dia. ASTM A325N, standard holes (dh = 13/16 in.).

Bolt spacing: 3 in. center-to-center vertically, 4 in. gage between rows (matches W12 flange workable gage). Edge distance: 1.5 in. from plate edges.


Step 4: Flange Plate Tension Yielding (AISC J4.1)

Per outer plate:

R_n = Fy × A_g = 50 × 4.500 = 225.0 kips
phi R_n = 0.90 × 225.0 = 202.5 kips

For outer + inner plates on one flange (4 plates total, but force shared):

Total phi R_n = 2 × 202.5 = 405.0 kips > 257.0 kips. **Tension yielding OK.**

Step 5: Flange Plate Tension Rupture (AISC J4.2)

Hole deduction: dh_eff = 13/16 + 1/16 = 7/8 in. per bolt (AISC B4.3b).

Per outer plate (2 rows, 3 bolts per row across the width = 2 holes per critical section):

A_n = (12.0 - 2 × 7/8) × 0.375 = (12.0 - 1.75) × 0.375 = 10.25 × 0.375 = 3.844 in.²
A_e = U × A_n = 1.0 × 3.844 = 3.844 in.² (U = 1.0, all elements connected)
R_n = Fu × A_e = 65 × 3.844 = 249.9 kips
phi R_n = 0.75 × 249.9 = 187.4 kips per outer plate

For outer + inner plates:

Total phi R_n = 2 × 187.4 = 374.8 kips > 257.0 kips. **Tension rupture OK.**

Step 6: Flange Bolt Shear Check (AISC J3.6)

6 bolts per flange face (2 rows × 3 bolts), A325N single shear:

A_b = pi × 0.75² / 4 = 0.442 in.²
r_n = Fnv × A_b = 54 × 0.442 = 23.9 kips per bolt
phi r_n = 0.75 × 23.9 = 17.9 kips per bolt

6 bolts per face:

phi R_n = 6 × 17.9 = 107.4 kips per face

This is per outer plate. For both outer and inner plates with independent bolt groups:

Total phi R_n = 2 × 107.4 = 214.8 kips

Per AISC Section B3.6, the minimum splice strength must be at least 50% of column strength. This bolt group transfers flange force through the splice plates. However, 214.8 kips < 257.0 kips -- not adequate.

Increase to 7/8 in. diameter A325N bolts:

A_b = pi × 0.875² / 4 = 0.601 in.²
r_n = 54 × 0.601 = 32.5 kips
phi r_n = 0.75 × 32.5 = 24.4 kips per bolt
phi R_n = 6 × 24.4 = 146.4 kips per face
Total = 2 × 146.4 = 292.8 kips > 257.0 kips. **Bolt shear OK.**

Step 7: Flange Bolt Bearing Check (AISC J3.10)

Bearing on outer flange plate (tp = 0.375 in., Fu = 65 ksi):

For edge bolts (Le = 1.5 in.):

L_c = 1.5 - (15/16)/2 = 1.5 - 0.469 = 1.031 in. (dh_eff = 15/16 in. for 7/8 in. bolt)
r_n = 1.2 × L_c × t × Fu = 1.2 × 1.031 × 0.375 × 65 = 30.2 kips
≤ 2.4 × d × t × Fu = 2.4 × 0.875 × 0.375 × 65 = 51.2 kips

For interior bolts (s = 3.0 in.):

L_c = 3.0 - 15/16 = 3.0 - 0.938 = 2.063 in.
r_n = 2.4 × 0.875 × 0.375 × 65 = 51.2 kips (bearing governs over tearout for interior bolts)

Per outer plate with 4 edge bolts + 2 interior bolts:

R_n_total = 4 × 30.2 + 2 × 51.2 = 120.8 + 102.4 = 223.2 kips
phi R_n = 0.75 × 223.2 = 167.4 kips per outer plate

For outer + inner:

Total = 2 × 167.4 = 334.8 kips > 257.0 kips. **Bolt bearing OK.**

Bearing on column flange (tf = 0.605 in., Fu = 65 ksi):

R_n_col_flange even higher due to thicker flange. **Flange bearing OK.**

Step 8: Flange Block Shear (AISC J4.3)

Check outer flange plate. Shear path: 2 vertical lines, each with 3 bolts at 3 in. spacing.

L_gv = 2 × (2 × 3.0 + 1.5) = 2 × 7.5 = 15.0 in. (both sides)
A_gv = 15.0 × 0.375 = 5.625 in.²
A_nv = [15.0 - 2 × (2.5 × 15/16)] × 0.375 = [15.0 - 2 × 2.344] × 0.375
     = [15.0 - 4.688] × 0.375 = 10.312 × 0.375 = 3.867 in.²

Tension path across plate width between bolt rows:

L_gt = 4.0 in. (gage)
A_gt = 4.0 × 0.375 = 1.500 in.²
A_nt = (4.0 - 1 × 15/16) × 0.375 = 3.063 × 0.375 = 1.148 in.²
R_n = 0.60 × Fu × A_nv + U_bs × Fu × A_nt
    = 0.60 × 65 × 3.867 + 1.0 × 65 × 1.148
    = 150.8 + 74.6 = 225.4 kips

Upper bound: 0.60 × Fy × A_gv + U_bs × Fu × A_nt
    = 0.60 × 50 × 5.625 + 1.0 × 65 × 1.148
    = 168.8 + 74.6 = 243.4 kips

Governing R_n = 225.4 kips.

phi R_n = 0.75 × 225.4 = 169.1 kips per outer plate

For outer + inner:

Total = 2 × 169.1 = 338.1 kips > 257.0 kips. **Block shear OK.**

Step 9: Web Splice Design

The column web splice transfers V_u = 8.0 kips and provides alignment. Use 2 PL 8 × 1/4 in. web splice plates (one each side), ASTM A36 (Fy = 36 ksi, Fu = 58 ksi).

Bolt layout: 2 bolts per side, 3/4 in. A325N, single vertical row at 3 in. spacing.

Web Plate Shear Yielding:

A_gv = 8.0 × 0.25 = 2.000 in.² per plate
R_n = 0.60 × Fy × A_gv = 0.60 × 36 × 2.0 = 43.2 kips
phi R_n = 1.00 × 43.2 = 43.2 kips per plate
Total = 2 × 43.2 = 86.4 kips > 8.0 kips. **Shear OK.**

Web Bolt Shear (2 bolts):

phi R_n = 2 × 17.9 = 35.8 kips > 8.0 kips. **Bolt shear OK.**

Since V_u = 8.0 kips is small relative to even minimal capacities, web splice is adequate with significant reserve.


Step 10: Summary — Pass/Fail

Limit State Reference Demand Capacity D/C Ratio Status
Flange plate tension yielding AISC J4.1 257.0 k 405.0 k 0.635 PASS
Flange plate tension rupture AISC J4.2 257.0 k 374.8 k 0.686 PASS
Flange bolt shear (12 bolts) AISC J3.6 257.0 k 292.8 k 0.878 PASS
Flange bolt bearing (plate) AISC J3.10 257.0 k 334.8 k 0.768 PASS
Flange block shear AISC J4.3 257.0 k 338.1 k 0.760 PASS
Web plate shear yielding AISC J4.2 8.0 k 86.4 k 0.093 PASS
Web bolt shear (2 bolts) AISC J3.6 8.0 k 35.8 k 0.223 PASS
Minimum splice (50% Pn) AISC B3.6 360.0 k 420.0 k PASS

All checks pass. The governing limit state is flange bolt shear at D/C = 0.878 (with 7/8 in. A325N bolts and 6 bolts per face). This is an efficient design.

Final Splice Details:


Related Calculators

Verify column splices with the Splice Connection Calculator. Check the column's base capacity first using the Column Capacity Calculator. For bolted connection components, use the Bolted Connection Calculator.