UK Universal Column Guide — UKC Sizes, Properties, S275/S355 Applications

Complete reference for UK Universal Column (UKC) sections — the standard hot-rolled H-column specified for compression members in British structural steelwork. Covers the full UKC range from 152x152x23 to 356x406x634, buckling behaviour per EN 1993-1-1, axial capacity estimation, and selection guidance for typical UK building frames.

Quick access: Section Properties Search | Column Capacity Calculator | UKB Beam Guide | Base Plate Design


UKC Designation System

UKC sections use the same metric convention as UKB:

Element Description Example
Nominal depth (mm) Approx. overall depth 254
Flange width (mm) Approx. flange width 254
Mass (kg/m) Self-weight 107
Type UKC UKC

Full designation: 254x254x107 UKC

UKC sections have near-square profiles (aspect ratio ~1.0), optimised for compression.


UKC Dimensional Range

152x152 UKC Series (Light Columns)

Designation Depth (mm) Width (mm) Web tw (mm) Flange tf (mm) Area (cm^2) Mass (kg/m) iy (cm) iz (cm)
152x152x23 152.4 152.2 5.8 6.8 29.2 23.0 6.54 3.70
152x152x30 157.6 152.9 6.5 9.4 38.3 30.0 6.76 3.82
152x152x37 161.8 154.4 8.0 11.5 47.1 37.0 6.85 3.87
152x152x44 166.0 155.9 9.4 13.6 56.1 44.0 6.93 3.91
152x152x51 170.2 157.4 11.0 15.7 64.9 51.0 7.00 3.95

203x203 UKC Series (Medium Columns)

The most common series for 3-8 storey building columns.

Designation Depth (mm) Width (mm) Web tw (mm) Flange tf (mm) Area (cm^2) Mass (kg/m) iy (cm) iz (cm)
203x203x46 203.2 203.6 7.2 11.0 58.7 46.1 8.82 5.13
203x203x52 206.2 204.3 7.9 12.5 66.3 52.0 8.90 5.17
203x203x60 209.6 205.8 9.4 14.2 76.4 60.0 8.96 5.19
203x203x71 215.8 206.4 10.0 17.3 90.4 71.0 9.17 5.30
203x203x86 222.2 207.9 12.7 20.5 110 86.1 9.27 5.34
203x203x100 228.6 210.3 14.5 23.7 127 100 9.38 5.39

254x254 UKC Series (Heavy Columns)

For 6-15 storey buildings, transfer structures, and industrial framing.

Designation Depth (mm) Width (mm) Web tw (mm) Flange tf (mm) Area (cm^2) Mass (kg/m) iy (cm) iz (cm)
254x254x73 254.1 254.6 8.6 14.2 93.1 73.1 11.1 6.46
254x254x89 260.3 256.3 10.3 17.3 113 88.9 11.2 6.52
254x254x107 266.7 258.8 12.8 20.5 136 107 11.3 6.57
254x254x132 276.3 261.3 15.3 25.3 168 132 11.5 6.66
254x254x167 289.1 265.2 19.2 31.7 213 167 11.7 6.78

305x305 and 356x368/406 UKC (Very Heavy)

Designation Depth (mm) Width (mm) Web tw (mm) Flange tf (mm) Area (cm^2) Mass (kg/m) iy (cm) iz (cm)
305x305x97 307.9 305.3 9.9 15.4 123 96.9 13.4 7.73
305x305x118 314.5 307.4 12.0 18.7 150 118 13.6 7.82
305x305x137 320.5 309.2 13.8 21.7 174 137 13.7 7.89
305x305x158 327.1 311.2 15.8 25.0 201 158 13.9 7.97
305x305x198 339.9 314.5 19.1 31.4 252 198 14.2 8.12
305x305x240 352.5 318.4 23.0 37.7 306 240 14.5 8.30
305x305x283 365.3 322.2 26.8 44.1 360 283 14.8 8.47
356x368x129 355.6 368.6 10.4 17.5 164 129 15.2 9.43
356x368x153 362.0 370.5 12.3 20.7 195 153 15.4 9.52
356x368x177 368.2 372.6 14.4 23.8 226 177 15.5 9.59
356x368x202 374.6 374.7 16.5 27.0 257 202 15.6 9.68
356x406x235 381.0 394.8 18.4 30.2 299 235 16.3 10.3
356x406x287 393.6 399.0 22.6 36.5 366 287 16.5 10.5
356x406x340 406.4 403.0 26.6 42.9 433 340 16.8 10.6
356x406x393 419.0 407.0 30.6 49.2 501 393 17.0 10.8
356x406x467 436.6 412.4 35.8 58.0 595 467 17.3 11.0
356x406x551 455.6 418.5 42.1 67.5 702 551 17.7 11.2
356x406x634 474.6 424.0 47.6 77.0 808 634 18.1 11.4

Heavier sections (above 400 kg/m) are special-order items. Confirm availability with Tata Steel.


Column Buckling per EN 1993-1-1

The buckling resistance of a UKC column:

Step 1 — Squash load: Npl,Rd = A x fy / gamma_M0

Step 2 — Elastic critical load: Ncr = pi^2 x E x I / Lcr^2

Step 3 — Slenderness: lambda_bar = sqrt(A x fy / Ncr)

Step 4 — Reduction factor chi: UKC sections (h/b <= 1.2, tf <= 100 mm) use buckling curve 'c' for weak axis (alpha = 0.49).

Step 5 — Buckling resistance: Nb,Rd = chi x A x fy / gamma_M1

Worked example — 254x254x107 UKC in S355, Lcr = 4.0 m:


Grade Selection

Grade fy (MPa) Npl,Rd (kN) chi (Lcr=4m) Nb,Rd (kN)
S275 275 3,740 0.718 2,685
S355 355 4,828 0.670 3,235

S355 provides ~21% capacity increase for ~5-10% cost premium.

When S355 provides value:

When S275 is appropriate:


Typical Applications

Application UKC range Axial load Key considerations
Residential (3-5 storeys) 152x152 to 203x203 500-3,000 kN Base plate, fire protection
Offices (5-12 storeys) 203x203 to 305x305 2,000-8,000 kN Sway stiffness, splices
High-rise (15+ storeys) 305x305 to 356x406 6,000-25,000 kN Axial shortening, concrete fill
Transfer columns 356x368 to 356x406 10,000-30,000 kN Bearing, stiffeners
Portal frame legs 305x305 to 356x368 Combined bending + axial

FAQ

What is the weight difference between UKC and HEB for the same depth?

For approximately equivalent capacity: 254x254x107 UKC (107 kg/m, iz = 6.57 cm) vs HEB 260 (93 kg/m, iz = 6.58 cm). The HEB achieves similar buckling resistance at 13% less weight because parallel flanges give a slightly better iz/A ratio. However, UKC and HEB have different connection geometry — do not substitute without full re-check.

What buckling curve applies?

Curve 'c' (alpha = 0.49) for weak-axis buckling per UK NA to EN 1993-1-1. Strong-axis uses curve 'b' (alpha = 0.34) but rarely governs.

What is the standard UK approach to fire protection of UKC columns?

Three methods: (1) intumescent paint for up to 120 min; (2) board encasement for 60-180 min; (3) concrete encasement for highest ratings. Fire engineering per EN 1993-1-2 can demonstrate that heavier UKC sections achieve 30-60 min with reduced protection.


References