----------------- | ----------- | ---------- | ----------- | -------- | | Bolt shear + bearing | J3.6, J3.10 | Cl 9.3 | Cl 3.6.1 | Cl 13.12 | | Weld strength | J2.2 | Cl 9.7 | Cl 4.5 | Cl 13.13 | | Block shear | J4.3 | Cl 9.2.2 | Cl 3.10.2 | Cl 13.11 | | Prying action | J3.6 | Cl 9.3.2.2 | Cl 6.2.4 | Cl 13.12 | | Shear tab flexure | J4.5 | Cl 9.3.1 | Cl 6.2 | Cl 13.10 | | Web local yielding | J10.2 | Cl 5.13 | Cl 6.2.6.2 | Cl 14.3 | | Web crippling | J10.3 | Cl 5.13 | Cl 6.2.6.3 | Cl 14.3 |

Prying Action Overview

Prying action occurs in tension-loaded bolted connections (such as end plates) where bolt tension induces flexure in the connected plate, amplifying the actual tension demand on the bolts. AISC 360-22 Section J3.6 provides the prying action equations. The key parameters are the plate thickness (tp), bolt gauge (g), and the ratio of flange flexural stiffness to bolt axial stiffness. Increasing plate thickness is the most effective way to reduce prying amplification.

Design Guidance

Key Design Parameters

When performing structural steel design calculations, the following parameters govern the design:

Design Procedure

  1. Establish design criteria: code edition, material grade, design method (LRFD/ASD)
  2. Determine loads and applicable load combinations
  3. Analyze structure for internal forces (axial, shear, moment, torsion)
  4. Check member strength for all applicable limit states
  5. Verify serviceability criteria (deflection, drift, vibration)
  6. Detail connections to transfer calculated forces

Worked Example

Problem: Design a structural element for the following conditions:

Span/Height: 15 ft | Load: 50 kips (factored) | Section: W12×65 (A992, Fy=50 ksi) | Code: AISC 360-22 LRFD

Solution:

Result: Section is adequate if φcPn ≥ Pu (50 kips).

Frequently Asked Questions

What design codes does this calculator support?

This calculator supports AISC 360-22 (US LRFD and ASD), EN 1993-1-1 (Eurocode 3), AS 4100 (Australia), and CSA S16 (Canada). Each code edition is verified against the respective design standard. Select your governing code in the calculator interface before entering loads.

How accurate are the results from this calculator?

Results are verified against published design examples and textbook solutions. The calculation engine uses the exact code provisions from the applicable standard. Always verify critical results independently and have designs reviewed by a licensed Professional Engineer. Results are preliminary until independently verified.

Can I save and export my calculations?

Registered users can save calculations to their account for later reference. Currently 10 calculations per hour and 50 per day are available on the free tier. Pro subscription ($49/month) increases limits to 500 calculations per month with PDF export capability.

Frequently Asked Questions

What is the most common governing limit state for steel connections? For shear connections, bolt shear or bearing at the bolt holes typically governs. For moment connections, either weld strength at the beam flange or prying action in the end plate governs. Block shear frequently governs in gusset plates and coped beams. Always check all applicable limit states — the weakest link determines the connection capacity.

How does block shear differ from bolt bearing failure? Block shear is a rupture failure along a path combining shear planes (parallel to load) and tension planes (perpendicular to load), causing a block of material to tear out. Bolt bearing is a localized crushing failure around a single bolt hole. Block shear typically governs when bolt groups are close to a free edge; bearing governs for interior bolts with adequate edge distance.

What is the minimum edge distance for bolt holes in structural steel? AISC 360-22 Table J3.4 specifies minimum edge distances by bolt diameter and edge type (sheared or rolled/plasma-cut). For 3/4-inch bolts, minimum edge distance is 1-1/8 inches for sheared edges and 7/8 inches for rolled edges. These are absolute minimums — practical edge distances for full bearing capacity are 2-3 times the bolt diameter.

Is this connection check calculator free? Yes, completely free with unlimited calculations. No registration required.

Block Shear vs Net Section Fracture

Block shear rupture and net section fracture are two distinct tension failure modes that frequently control the capacity of bolted steel connections. While both involve fracture across the net section, their mechanics, governing equations, and design sensitivities differ significantly.

Block Shear Rupture (AISC 360-22 Section J4.3)

Block shear is a limit state where a block of material tears out along a path that combines shear planes (parallel to the applied force) and a tension plane (perpendicular to the applied force). It occurs when bolt groups are relatively compact and positioned near a member edge.

Governing equation (AISC 360-22 Eq J4-5): Rn = 0.60 x Fu x Anv + Ubs x Fu x Ant <= 0.60 x Fy x Agv + Ubs x Fu x Ant

Where:

Worked comparison — block shear vs net section:

Consider a 3/8-inch thick A36 plate (Fu = 58 ksi) with a single line of three 3/4-inch A325 bolts at 3-inch pitch spaced 1-1/2 inches from the plate edge. Applied tension = 45 kips.

Block shear check:

Net section fracture check (AISC 360-22 Section D2):

When Each Mode Governs

Criterion Block Shear Net Section Fracture
Typical section Gusset plates, coped beams, shear tabs Tension members, hanger plates
Critical dimension Edge distance + bolt spacing pattern Net width across the critical bolt line
Influenced by Shear plane length, number of shear planes Number of bolts transverse to load
Material property Fu (fracture), Fy cap on shear Fu only
Phi factor 0.75 0.75
AISC section J4.3 D2 (tension members), J4.1 (connecting elements)

Ductile vs Brittle Failure Considerations

Block shear can be designed for either ductile or brittle behavior:

Net section fracture is always a brittle failure mode — there is no yielding precursor. For this reason, AISC 360 requires that the design tensile strength based on net section fracture (phi x Fu x Ae) be at least as large as the design yield strength (phi x Fy x Ag) to ensure yielding precedes fracture. A commonly overlooked check: if Ae/Ag < Fy/Fu, net section fracture governs before gross section yield.

Design Strategies to Prevent Block Shear and Net Section Fracture

  1. Increase edge distance: Moving bolts further from the edge increases both shear plane length and tension plane width.
  2. Stagger bolt rows: Staggering bolts increases net area for the net section check (AISC 360 Section B4.3b).
  3. Increase plate thickness: Both block shear and net section capacity scale linearly with thickness.
  4. Use larger bolt spacing: Increases shear plane length for block shear resistance.
  5. Specify a higher Fu/Fy ratio steel: A572 Gr 50 (Fu/Fy = 65/50 = 1.30) provides better post-yield fracture resistance than A36 (Fu/Fy = 58/36 = 1.61) for net section, but A36's lower Fy reduces shear yielding capacity for block shear.

Related pages

Disclaimer (educational use only)

This page is provided for general technical information and educational use only. It does not constitute professional engineering advice. All structural designs must be verified by a licensed Professional Engineer (PE) or Structural Engineer (SE). The site operator disclaims liability for any loss or damage arising from the use of this page.