Australian Column Design — AS 4100 Compression and Buckling Guide

Quick access: [[Australian Steel Grades|/reference/australian-steel-grades/]] | [[Australian Steel Properties|/reference/australian-steel-properties/]] | [[Australian Beam Sizes|/reference/au-beam-sizes/]] | [[Australian Bolt Capacity|/reference/australian-bolt-capacity/]] | [[AS 4100 Beam Design|/reference/as4100-beam-design-example/]] | [[All Australian References|/reference/]]


Comprehensive guide for column axial compression design per AS 4100:2020 Clause 6. Covers section capacity (φNs), member buckling capacity (φNc), buckling curves, effective length, and slenderness limits.

Compression Design Procedure

Section capacity: φNs = φ × fy × Ag (Clause 6.2)

Member capacity: φNc = φ × αc × Ns (Clause 6.3)

αc from AS 4100 Table 6.2.4 based on modified slenderness λn: λn = (Le/r) × √(fy/250)

Buckling curve selection based on section type (Table 6.2.3):

Section Type Axis αb Curve
UB (flange ≥ 0.5×depth) Major 0.5 SHC
UB (flange < 0.5×depth) Major −1.0 AISC
UC Both 0.0 AISC
CHS (cold-formed) −0.5 AISC
SHS/RHS (cold-formed) Both −0.5 AISC
Welded I-section Major 0.5 SHC
Welded I-section Minor −0.5 AISC

αb: 0.0 = AISC curve (intermediate), −1.0 = AISC lower curve, +0.5 = SHC curve (higher capacity)

αc Values from λn

λn αb = 1.0 αb = 0.5 αb = 0.0 αb = −0.5 αb = −1.0
10 0.997 0.996 0.995 0.994 0.993
25 0.986 0.979 0.970 0.960 0.947
50 0.945 0.915 0.877 0.831 0.778
75 0.880 0.814 0.732 0.643 0.556
100 0.799 0.692 0.573 0.462 0.370
125 0.711 0.569 0.437 0.332 0.253
150 0.626 0.460 0.332 0.240 0.177

Column Capacity Tables — UC Sections

Section Ag (mm²) φNs (kN) Le=3m φNc Le=4m φNc Le=5m φNc Le=6m φNc
150UC37 4,740 1,248 1,180 1,120 1,045 960
200UC52 6,670 1,756 1,660 1,575 1,470 1,350
250UC89 11,400 3,002 2,840 2,690 2,510 2,300
310UC137 17,500 4,607 4,360 4,130 3,850 3,530
310UC158 20,100 5,292 5,010 4,740 4,420 4,050

Values: Grade 300, αb=0.0, pin-ended (k=1.0).

Worked Example

Problem: 310UC137 column, L=5.0 m, braced frame, pinned base, top GB=1.5. N*=2,800 kN. Grade 300.

Solution:

  1. Effective length: GA=10 (pinned), GB=1.5 → k=0.92 from alignment chart
  2. Le = 0.92×5,000 = 4,600 mm
  3. Slenderness: λn = (4,600/87.4) × √(300/250) = 52.6 × 1.095 = 57.6
  4. αb=0.0 (UC section). From table: αc ≈ 0.82 (interpolated)
  5. φNc = 0.90 × 0.82 × 300 × 17,500 = 3,874 kN > 2,800 OK
  6. Check: N*/φNc = 0.72 < 1.0 OK

Design Resources

FAQ

What buckling curve is used for UC sections? αb=0.0 (AISC curve) per AS 4100 Table 6.2.3 for UC sections. This is the intermediate curve.

How does effective length affect column capacity? Capacity decreases rapidly with increasing Le. A 310UC137 at Le=3m has φNc=4,360 kN vs Le=6m φNc=3,530 kN (19% reduction).

What is the maximum slenderness for columns? AS 4100 Clause 6.1 limits Le/r ≤ 200 for primary members and ≤ 300 for secondary members.


Educational Use Only — This reference is for educational and preliminary design purposes only. All structural designs must be independently verified by a licensed Professional Engineer (PE) or Structural Engineer (SE) in accordance with AS 4100:2020 and all applicable Australian Standards. Results are not for construction.