Australian Moment Frame — AS 4100 Connection Design

Quick access: [[Australian Steel Grades|/reference/australian-steel-grades/]] | [[Australian Steel Properties|/reference/australian-steel-properties/]] | [[Australian Beam Sizes|/reference/au-beam-sizes/]] | [[Australian Bolt Capacity|/reference/australian-bolt-capacity/]] | [[AS 4100 Beam Design|/reference/as4100-beam-design-example/]] | [[All Australian References|/reference/]]


Reference for moment-resisting frame design per AS 4100:2020 and AS 1170.4:2007. Covers steel moment frames (SMF, OMF), panel zone shear, beam-to-column connection detailing, and capacity design requirements.

Frame Classification

Type Ductility Connection Type Drift Limit Use
OMF (Ordinary) D1 (μ=1.25) Partial strength H/400 Low seismic
IMF (Intermediate) D2 (μ=2.0) Flange welded + web bolted H/300 Moderate seismic
SMF (Special) D3-D4 (μ=3-4) Fully welded + continuity plates H/200 High seismic

Connection Design — AS 4100 Clause 9

Full-strength connection: Must develop ≥ φMs of the beam

Beam-to-column connection checks:

Component Check
Beam flange welds Full-pen butt weld or fillet (capacity ≥ flange force)
Beam web bolting Shear + moment from flange eccentricity
Column flange (bending) Continuity plate required if too thin
Column web (panel zone) Shear yield + buckling check
Column web (compression) Stiffener required if concentrated force exceeds web capacity

Panel Zone Design — Clause 5.9

Panel zone shear: Vpz = (Mb1 / db1 + M*b2 / db2) − Vcol

Capacity: φVpz = 0.90 × 0.60 × fy × dc × twc

If φVpz < V*pz: Add web doubler plates or increase column section.

Column Section Panel Zone Capacity (kN) Double Plate Required
200UC52 480 kN At >400 kN beam moment
250UC89 820 kN At >700 kN beam moment
310UC137 1,320 kN At >1,200 kN beam moment
310UC158 1,550 kN At >1,400 kN beam moment

Worked Example

Problem: SMF connection, 410UB59.7 beam to 310UC137 column. Beam M*=350 kNm. Check panel zone.

Solution:

  1. Beam flange force: Ff = 350 / 0.388 = 902 kN
  2. Panel zone shear: Vpz ≈ 902 × 2 = 1,804 kN
  3. Column web (12 mm): φVpz = 0.90×0.60×300×327×12 = 636 kN << 1,804
  4. Add doubler plate: Need Vpz = 1,804 - 636 = 1,168 kN from doubler
  5. Doubler thickness: tp = 1,168×10³/(0.90×0.60×300×327) = 22 mm
  6. Weld doubler plate to column flanges with 8 mm fillet welds.

Design Resources

FAQ

What is panel zone shear? The shear force in the column web within the beam-column joint region. Critical for moment frame connections. Per AS 4100 Clause 5.9.

When are continuity plates needed? When column flange thickness is insufficient to resist beam flange forces without bending. Typically required for UB → UC connections.

What is the SMF connection requirement? Full-strength connection that develops ≥ φMs of the beam. Requires full-pen butt weld at flanges, web bolting or welding, and continuity plates.


Educational Use Only — This reference is for educational and preliminary design purposes only. All structural designs must be independently verified by a licensed Professional Engineer (PE) or Structural Engineer (SE) in accordance with AS 4100:2020 and all applicable Australian Standards. Results are not for construction.