100PFC AS/NZS 3679.1 Grade 300 — Australian Parallel Flange Channel Section Properties

100PFC is an Australian PFC (Parallel Flange Channel) per AS/NZS 3679.1 hot-rolled structural steel section. Standard Australian PFC dimensions. Verify against Liberty OneSteel / InfraBuild section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 100 mm
Flange Width (bf) 50 mm
Flange Thickness (tf) 6.5 mm
Web Thickness (tw) 4.0 mm
Cross-Sectional Area (A) 10.0 cm²
Mass 10.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 164 14 cm⁴
Elastic Section Modulus (S) 33 5 cm³
Plastic Section Modulus (Z) 38 8 cm³
Radius of Gyration (r) 4.06 1.17 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 1 cm⁴
Distance Between Flange Centroids (ho) 9.35 cm

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 100 mm deep — a shallow section suitable for girts, rails, struts, and mild-load secondary members.

Key Design Checks (AS 4100)

Check Formula This Section
Plastic moment Mp = Zx × Fy 11 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 164 cm⁴
Torsion St. Venant = GJ/L J = 1 cm⁴
Column buckling KL/r → Fcr r_x = 4.06 cm

Design Notes

Verification (AS 4100): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — 100pfc

Scenario: Commercial office floor — typical open-plan layout with raised floor. Simply supported channel, 2.0 m span, 2.4 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (16.8 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 7.2 × (2000)⁴ / (384 × 200000 × 1,640,000)

Δ_LL = 4.6 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 2000 / 300 = 6.7 mm

Step 3 — Dead + live deflection:

Δ_total = 10.7 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per AS 4100) does not exceed φMn = 10 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AS 4100 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.