180UB84 AS/NZS 3679.1 Grade 300 — Australian Universal Beam Section Properties

180UB84 is an Australian UB (Universal Beam) per AS/NZS 3679.1 hot-rolled structural steel section. Standard Australian UB dimensions. Verify against Liberty OneSteel / InfraBuild section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 180 mm
Flange Width (bf) 130 mm
Flange Thickness (tf) 24.0 mm
Web Thickness (tw) 11.0 mm
Cross-Sectional Area (A) 76.9 cm²
Mass 84.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 4,037 880 cm⁴
Elastic Section Modulus (S) 449 135 cm³
Plastic Section Modulus (Z) 535 207 cm³
Radius of Gyration (r) 7.24 3.38 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 126 cm⁴
Distance Between Flange Centroids (ho) 15.60 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by AS 4100. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 4,037 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 180 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (AS 4100)

Check Formula This Section
Plastic moment Mp = Zx × Fy 161 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 4,037 cm⁴
Torsion St. Venant = GJ/L J = 126 cm⁴
Column buckling KL/r → Fcr r_x = 7.24 cm

Design Notes

Verification (AS 4100): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital ward beam — 180ub84

Scenario: Hospital ward — strict deflection limits for medical equipment and services. Simply supported I-section, 3.2 m span, 2.1 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (14.7 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.3 × (3240)⁴ / (384 × 200000 × 40,370,000)

Δ_LL = 1.1 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 3240 / 360 = 9.0 mm

Step 3 — Dead + live deflection:

Δ_total = 2.6 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per AS 4100) does not exceed φMn = 144 kN·m. Also confirm shear resistance and bearing details at the supports.