250UC101 AS/NZS 3679.1 Grade 300 — Australian Universal Column Section Properties

250UC101 is an Australian UC (Universal Column) per AS/NZS 3679.1 hot-rolled structural steel section. Standard Australian UC dimensions. Verify against Liberty OneSteel / InfraBuild section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 260 mm
Flange Width (bf) 255 mm
Flange Thickness (tf) 12.0 mm
Web Thickness (tw) 8.0 mm
Cross-Sectional Area (A) 80.1 cm²
Mass 101.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 10,294 3,317 cm⁴
Elastic Section Modulus (S) 792 260 cm³
Plastic Section Modulus (Z) 870 394 cm³
Radius of Gyration (r) 11.34 6.44 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 33 cm⁴
Distance Between Flange Centroids (ho) 24.80 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by AS 4100. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 10,294 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 260 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (AS 4100)

Check Formula This Section
Plastic moment Mp = Zx × Fy 261 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 10,294 cm⁴
Torsion St. Venant = GJ/L J = 33 cm⁴
Column buckling KL/r → Fcr r_x = 11.34 cm

Design Notes

Verification (AS 4100): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Industrial floor beam — 250uc101

Scenario: Light industrial floor — forklift traffic and storage considerations. Simply supported I-section, 5.2 m span, 3 m tributary width. Service loads: 5.0 kPa dead + 7.5 kPa live (37.5 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 22.5 × (5200)⁴ / (384 × 200000 × 102,940,000)

Δ_LL = 10.4 mm

Step 2 — Deflection limit (L/250):

Δ_limit = L / 250 = 5200 / 250 = 20.8 mm

Step 3 — Dead + live deflection:

Δ_total = 17.3 mm

Step 4 — Design check:

✓ Live load deflection is within the L/250 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per AS 4100) does not exceed φMn = 235 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AS 4100 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.