250UC149 AS/NZS 3679.1 Grade 300 — Australian Universal Column Section Properties

250UC149 is an Australian UC (Universal Column) per AS/NZS 3679.1 hot-rolled structural steel section. Standard Australian UC dimensions. Verify against Liberty OneSteel / InfraBuild section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 260 mm
Flange Width (bf) 255 mm
Flange Thickness (tf) 17.5 mm
Web Thickness (tw) 12.0 mm
Cross-Sectional Area (A) 116.3 cm²
Mass 149.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 14,283 4,839 cm⁴
Elastic Section Modulus (S) 1,099 380 cm³
Plastic Section Modulus (Z) 1,234 577 cm³
Radius of Gyration (r) 11.08 6.45 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 104 cm⁴
Distance Between Flange Centroids (ho) 24.25 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by AS 4100. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 14,283 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 260 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (AS 4100)

Check Formula This Section
Plastic moment Mp = Zx × Fy 370 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 14,283 cm⁴
Torsion St. Venant = GJ/L J = 104 cm⁴
Column buckling KL/r → Fcr r_x = 11.08 cm

Design Notes

Verification (AS 4100): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Car park beam — 250uc149

Scenario: Multi-storey car park — asphalt wearing surface included. Simply supported I-section, 5.2 m span, 2.7 m tributary width. Service loads: 6.0 kPa dead + 2.5 kPa live (23.0 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.8 × (5200)⁴ / (384 × 200000 × 142,830,000)

Δ_LL = 2.2 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 5200 / 300 = 17.3 mm

Step 3 — Dead + live deflection:

Δ_total = 7.6 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per AS 4100) does not exceed φMn = 333 kN·m. Also confirm shear resistance and bearing details at the supports.