310UB67 AS/NZS 3679.1 Grade 300 — Australian Universal Beam Section Properties

310UB67 is an Australian UB (Universal Beam) per AS/NZS 3679.1 hot-rolled structural steel section. Standard Australian UB dimensions. Verify against Liberty OneSteel / InfraBuild section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 310 mm
Flange Width (bf) 160 mm
Flange Thickness (tf) 12.0 mm
Web Thickness (tw) 7.0 mm
Cross-Sectional Area (A) 58.4 cm²
Mass 67.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 9,894 820 cm⁴
Elastic Section Modulus (S) 638 103 cm³
Plastic Section Modulus (Z) 715 157 cm³
Radius of Gyration (r) 13.01 3.75 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 22 cm⁴
Distance Between Flange Centroids (ho) 29.80 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by AS 4100. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 9,894 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 310 mm deep, this section is common for floor beams, portal frame rafters, and columns in commercial and industrial buildings.

Key Design Checks (AS 4100)

Check Formula This Section
Plastic moment Mp = Zx × Fy 215 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 9,894 cm⁴
Torsion St. Venant = GJ/L J = 22 cm⁴
Column buckling KL/r → Fcr r_x = 13.01 cm

Design Notes

Verification (AS 4100): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Residential floor beam — 310ub67

Scenario: Residential apartment floor — partition allowance included in dead load. Simply supported I-section, 8.1 m span, 3 m tributary width. Service loads: 3.0 kPa dead + 2.0 kPa live (15.0 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.0 × (8060)⁴ / (384 × 200000 × 98,940,000)

Δ_LL = 16.7 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 8060 / 360 = 22.4 mm

Step 3 — Dead + live deflection:

Δ_total = 41.7 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per AS 4100) does not exceed φMn = 193 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AS 4100 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.