380PFC AS/NZS 3679.1 Grade 300 — Australian Parallel Flange Channel Section Properties

380PFC is an Australian PFC (Parallel Flange Channel) per AS/NZS 3679.1 hot-rolled structural steel section. Standard Australian PFC dimensions. Verify against Liberty OneSteel / InfraBuild section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 380 mm
Flange Width (bf) 100 mm
Flange Thickness (tf) 16.0 mm
Web Thickness (tw) 10.0 mm
Cross-Sectional Area (A) 66.8 cm²
Mass 60.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 14,119 270 cm⁴
Elastic Section Modulus (S) 743 54 cm³
Plastic Section Modulus (Z) 885 89 cm³
Radius of Gyration (r) 14.54 2.01 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 39 cm⁴
Distance Between Flange Centroids (ho) 36.40 cm

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 380 mm deep, this section is common for floor beams, portal frame rafters, and columns in commercial and industrial buildings.

Key Design Checks (AS 4100)

Check Formula This Section
Plastic moment Mp = Zx × Fy 266 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 14,119 cm⁴
Torsion St. Venant = GJ/L J = 39 cm⁴
Column buckling KL/r → Fcr r_x = 14.54 cm

Design Notes

Verification (AS 4100): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital ward beam — 380pfc

Scenario: Hospital ward — strict deflection limits for medical equipment and services. Simply supported channel, 6.8 m span, 2.1 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (14.7 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.3 × (6840)⁴ / (384 × 200000 × 141,190,000)

Δ_LL = 6.4 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 6840 / 360 = 19.0 mm

Step 3 — Dead + live deflection:

Δ_total = 14.8 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per AS 4100) does not exceed φMn = 239 kN·m. Also confirm shear resistance and bearing details at the supports.