W1000x222 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W40X149 per AISC A6. Approx. equivalent of W40X149. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 970.3 mm
Flange Width (bf) 299.7 mm
Flange Thickness (tf) 21.1 mm
Web Thickness (tw) 16.0 mm
Cross-Sectional Area (A) 282.6 cm²
Mass 221.7 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 407,905 9,532 cm⁴
Elastic Section Modulus (S) 8,407 636 cm³
Plastic Section Modulus (Z) 9,799 1,019 cm³
Radius of Gyration (r) 38.10 5.82 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 390 cm⁴
Warping Constant (Cw) 21,480,000 cm⁶
Distance Between Flange Centroids (ho) 95.00 cm
Effective Radius (rts) 7.34 cm

Imperial Reference

Property Value Unit
Depth (d) 38.20 in
Flange Width (bf) 11.80 in
Area (A) 43.80 in²
Weight 149 lb/ft

Section Profile Summary

Hot-rolled W-shape with Sx = 8,407 cm³. The section is well-suited for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 970.3 mm deep and 221.7 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 3,430 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 407,905 cm⁴
Torsion St. Venant = GJ/L J = 390 cm⁴
Column buckling KL/r → Fcr r_x = 38.1 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital ward beam — w1000x222

Scenario: Hospital ward — strict deflection limits for medical equipment and services. Simply supported wide flange, 21.3 m span, 2.1 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (14.7 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.3 × (21347)⁴ / (384 × 200000 × 4,079,050,000)

Δ_LL = 20.9 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 21347 / 360 = 59.3 mm

Step 3 — Dead + live deflection:

Δ_total = 48.7 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 3,087 kN·m. Also confirm shear resistance and bearing details at the supports.