W1000x320 G40.21 350W — Canadian W-Shape Section Properties
Approximate equivalent of W40X215 per AISC A6. Approx. equivalent of W40X215. Verify against CISC Handbook.
Dimensions (Metric)
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 990.6 | mm |
| Flange Width (bf) | 401.3 | mm |
| Flange Thickness (tf) | 31.0 | mm |
| Web Thickness (tw) | 16.5 | mm |
| Cross-Sectional Area (A) | 409.7 | cmÃÂò |
| Mass | 319.9 | kg/m |
Elastic Section Properties (Metric)
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 695,104 | 33,423 | cm⁴ |
| Elastic Section Modulus (S) | 14,076 | 1,655 | cmÃÂó |
| Plastic Section Modulus (Z) | 15,797 | 2,556 | cmÃÂó |
| Radius of Gyration (r) | 41.15 | 8.99 | cm |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 1,032 | cm⁴ |
| Warping Constant (Cw) | 76,254,000 | cm⁶ |
| Distance Between Flange Centroids (ho) | 96.01 | cm |
| Effective Radius (rts) | 10.64 | cm |
Imperial Reference
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 39.00 | in |
| Flange Width (bf) | 15.80 | in |
| Area (A) | 63.50 | inÃÂò |
| Weight | 215 | lb/ft |
Section Profile Summary
Hot-rolled W-shape with Sx = 14,076 cm³. The section is commonly specified for primary framing in multi-storey buildings, crane girders, and bridge stringers.
At 990.6 mm deep and 319.9 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.
Key Design Checks (CSA S16)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 5,529 kNÃÂ÷m |
| Deflection | Δ = 5wL⁴/(384EIx) | Use Ix = 695,104 cm⁴ |
| Torsion | St. Venant = GJ/L | J = 1,032 cm⁴ |
| Column buckling | KL/r → Fcr | r_x = 41.15 cm |
Design Notes
- Compactness: Most W-shapes in ASTM A992 satisfy the compact limits in CSA S16 Table B4.1b for flexure (λ ≤ λp). This allows full plastic moment Mp development before local buckling occurs.
- Flange local buckling (FLB): The flange slenderness ratio bf/2tf is compared against λpf = 0.38√(E/Fy) ≈ 9.0 for compact sections.
- Web local buckling (WLB): h/tw is checked against λpw = 3.76√(E/Fy) ≈ 72 for flexure, and a more restrictive limit for uniform compression.
- Lateral-torsional buckling (LTB): Lp ≈ 378.2 cm (plastic limit). For unbraced lengths ≤ Lp, the full plastic moment is available. Between Lp and Lr, linear interpolation per CSA S16 Eq. F2-2 applies.
Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Residential floor beam — w1000x320
Scenario: Residential apartment floor — partition allowance included in dead load. Simply supported wide flange, 19.8 m span, 3 m tributary width. Service loads: 3.0 kPa dead + 2.0 kPa live (15.0 kN/m total).
Given:
- Span L = 19812 mm (19.8 m)
- Total service load w = 15.0 kN/m
- Live load portion w_L = 6.0 kN/m
- Section w1000x320: Ix = 6951.0 × 10⁶ mm⁴, Sx = 14,076,000 mm³, Zx = 15,797,000 mm³
- Steel: fy = 350 MPa, E = 200,000 MPa
- Design moment resistance: φMn = 0.9 × Zx × fy = 4,976 kNÃÂ÷m
Step 1 — Live load deflection:
Δ_LL = 5 w_L L⁴ / (384 E Ix)
Δ_LL = 5 × 6.0 × (19812)⁴ / (384 × 200000 × 6,951,040,000)
Δ_LL = 8.7 mm
Step 2 — Deflection limit (L/360):
Δ_limit = L / 360 = 19812 / 360 = 55.0 mm
Step 3 — Dead + live deflection:
Δ_total = 21.6 mm
Step 4 — Design check:
✓ Live load deflection is within the L/360 limit.
Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 4,976 kNÃÂ÷m. Also confirm shear resistance and bearing details at the supports.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current CSA S16 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.