W1000x554 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W40X372 per AISC A6. Approx. equivalent of W40X372. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 1031.2 mm
Flange Width (bf) 408.9 mm
Flange Thickness (tf) 52.1 mm
Web Thickness (tw) 29.5 mm
Cross-Sectional Area (A) 709.7 cm²
Mass 553.5 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 1,232,041 59,105 cm⁴
Elastic Section Modulus (S) 23,925 2,900 cm³
Plastic Section Modulus (Z) 27,530 4,539 cm³
Radius of Gyration (r) 41.91 9.14 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 4,828 cm⁴
Warping Constant (Cw) 141,768,000 cm⁶
Distance Between Flange Centroids (ho) 98.04 cm
Effective Radius (rts) 11.00 cm

Imperial Reference

Property Value Unit
Depth (d) 40.60 in
Flange Width (bf) 16.10 in
Area (A) 110.00 in²
Weight 372 lb/ft

Section Profile Summary

Hot-rolled W-shape with Sx = 23,925 cm³. The section is a practical choice for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 1031.2 mm deep and 553.5 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 9,636 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1,232,041 cm⁴
Torsion St. Venant = GJ/L J = 4,828 cm⁴
Column buckling KL/r → Fcr r_x = 41.91 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: School classroom beam — w1000x554

Scenario: School building — tighter deflection limit for suspended ceiling integrity. Simply supported wide flange, 19.6 m span, 2.4 m tributary width. Service loads: 3.5 kPa dead + 3.0 kPa live (15.6 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 7.2 × (19593)⁴ / (384 × 200000 × 12,320,410,000)

Δ_LL = 5.6 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 19593 / 360 = 54.4 mm

Step 3 — Dead + live deflection:

Δ_total = 12.1 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 8,672 kN·m. Also confirm shear resistance and bearing details at the supports.