W200x15 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W8X10 per AISC A6. Approx. equivalent of W8X10. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 200.4 mm
Flange Width (bf) 100.1 mm
Flange Thickness (tf) 5.2 mm
Web Thickness (tw) 4.3 mm
Cross-Sectional Area (A) 19.1 cm²
Mass 14.9 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 1,282 87 cm⁴
Elastic Section Modulus (S) 128 17 cm³
Plastic Section Modulus (Z) 145 27 cm³
Radius of Gyration (r) 8.18 2.14 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 2 cm⁴
Warping Constant (Cw) 8,297 cm⁶
Distance Between Flange Centroids (ho) 19.53 cm
Effective Radius (rts) 2.57 cm

Imperial Reference

Property Value Unit
Depth (d) 7.89 in
Flange Width (bf) 3.94 in
Area (A) 2.96 in²
Weight 10 lb/ft

Section Profile Summary

Hot-rolled W-shape with Sx = 128 cm³. The section is appropriate for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 200.4 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 51 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1,282 cm⁴
Torsion St. Venant = GJ/L J = 2 cm⁴
Column buckling KL/r → Fcr r_x = 8.18 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: School classroom beam — w200x15

Scenario: School building — tighter deflection limit for suspended ceiling integrity. Simply supported wide flange, 3.4 m span, 2.4 m tributary width. Service loads: 3.5 kPa dead + 3.0 kPa live (15.6 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 7.2 × (3407)⁴ / (384 × 200000 × 12,820,000)

Δ_LL = 4.9 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 3407 / 360 = 9.5 mm

Step 3 — Dead + live deflection:

Δ_total = 10.7 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 46 kN·m. Also confirm shear resistance and bearing details at the supports.