W250x80 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W10X54 per AISC A6. Approx. equivalent of W10X54. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 256.5 mm
Flange Width (bf) 254.0 mm
Flange Thickness (tf) 15.6 mm
Web Thickness (tw) 9.4 mm
Cross-Sectional Area (A) 101.9 cm²
Mass 80.4 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 12,612 4,287 cm⁴
Elastic Section Modulus (S) 983 338 cm³
Plastic Section Modulus (Z) 1,091 513 cm³
Radius of Gyration (r) 11.10 6.50 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 76 cm⁴
Warping Constant (Cw) 622,920 cm⁶
Distance Between Flange Centroids (ho) 24.10 cm
Effective Radius (rts) 7.24 cm

Imperial Reference

Property Value Unit
Depth (d) 10.10 in
Flange Width (bf) 10.00 in
Area (A) 15.80 in²
Weight 54 lb/ft

Section Profile Summary

With Ix = 12,612 cm⁴, this wide flange is appropriate for long-span floor beams and transfer girders where stiffness controls the design.

At 256.5 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 382 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 12,612 cm⁴
Torsion St. Venant = GJ/L J = 76 cm⁴
Column buckling KL/r → Fcr r_x = 11.1 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Car park beam — w250x80

Scenario: Multi-storey car park — asphalt wearing surface included. Simply supported wide flange, 6.2 m span, 2.7 m tributary width. Service loads: 6.0 kPa dead + 2.5 kPa live (23.0 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.8 × (6156)⁴ / (384 × 200000 × 126,120,000)

Δ_LL = 5.0 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 6156 / 300 = 20.5 mm

Step 3 — Dead + live deflection:

Δ_total = 17.0 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 344 kN·m. Also confirm shear resistance and bearing details at the supports.