W310x253 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W12X170 per AISC A6. Approx. equivalent of W12X170. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 355.6 mm
Flange Width (bf) 320.0 mm
Flange Thickness (tf) 39.6 mm
Web Thickness (tw) 24.4 mm
Cross-Sectional Area (A) 322.6 cm²
Mass 253.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 68,678 21,519 cm⁴
Elastic Section Modulus (S) 3,851 1,349 cm³
Plastic Section Modulus (Z) 4,506 2,065 cm³
Radius of Gyration (r) 14.58 8.18 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 1,482 cm⁴
Warping Constant (Cw) 5,396,850 cm⁶
Distance Between Flange Centroids (ho) 31.50 cm
Effective Radius (rts) 9.40 cm

Imperial Reference

Property Value Unit
Depth (d) 14.00 in
Flange Width (bf) 12.60 in
Area (A) 50.00 in²
Weight 170 lb/ft

Section Profile Summary

With Ix = 68,678 cm⁴, this wide flange is suitable for long-span floor beams and transfer girders where stiffness controls the design.

At 355.6 mm deep, this section is common for floor beams, portal frame rafters, and columns in commercial and industrial buildings.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,577 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 68,678 cm⁴
Torsion St. Venant = GJ/L J = 1,482 cm⁴
Column buckling KL/r → Fcr r_x = 14.58 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Car park beam — w310x253

Scenario: Multi-storey car park — asphalt wearing surface included. Simply supported wide flange, 7.5 m span, 2.7 m tributary width. Service loads: 6.0 kPa dead + 2.5 kPa live (23.0 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.8 × (7468)⁴ / (384 × 200000 × 686,780,000)

Δ_LL = 2.0 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 7468 / 300 = 24.9 mm

Step 3 — Dead + live deflection:

Δ_total = 6.8 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 1,419 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current CSA S16 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.