W360x101 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W14X68 per AISC A6. Approx. equivalent of W14X68. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 355.6 mm
Flange Width (bf) 254.0 mm
Flange Thickness (tf) 18.3 mm
Web Thickness (tw) 10.5 mm
Cross-Sectional Area (A) 129.0 cm²
Mass 101.2 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 30,052 5,036 cm⁴
Elastic Section Modulus (S) 1,688 397 cm³
Plastic Section Modulus (Z) 1,885 605 cm³
Radius of Gyration (r) 15.27 6.25 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 125 cm⁴
Warping Constant (Cw) 1,444,530 cm⁶
Distance Between Flange Centroids (ho) 33.78 cm
Effective Radius (rts) 7.11 cm

Imperial Reference

Property Value Unit
Depth (d) 14.00 in
Flange Width (bf) 10.00 in
Area (A) 20.00 in²
Weight 68 lb/ft

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 30,052 cm⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 355.6 mm deep, this section is common for floor beams, portal frame rafters, and columns in commercial and industrial buildings.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 660 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 30,052 cm⁴
Torsion St. Venant = GJ/L J = 125 cm⁴
Column buckling KL/r → Fcr r_x = 15.27 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital ward beam — w360x101

Scenario: Hospital ward — strict deflection limits for medical equipment and services. Simply supported wide flange, 8.2 m span, 2.1 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (14.7 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.3 × (8179)⁴ / (384 × 200000 × 300,520,000)

Δ_LL = 6.1 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 8179 / 360 = 22.7 mm

Step 3 — Dead + live deflection:

Δ_total = 14.3 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 594 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current CSA S16 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.