W360x634 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W14X426 per AISC A6. Approx. equivalent of W14X426. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 475.0 mm
Flange Width (bf) 424.2 mm
Flange Thickness (tf) 77.2 mm
Web Thickness (tw) 47.8 mm
Cross-Sectional Area (A) 806.5 cm²
Mass 633.9 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 274,712 98,230 cm⁴
Elastic Section Modulus (S) 11,569 4,638 cm³
Plastic Section Modulus (Z) 14,240 7,112 cm³
Radius of Gyration (r) 18.44 11.02 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 13,777 cm⁴
Warping Constant (Cw) 38,664,000 cm⁶
Distance Between Flange Centroids (ho) 39.88 cm
Effective Radius (rts) 12.98 cm

Imperial Reference

Property Value Unit
Depth (d) 18.70 in
Flange Width (bf) 16.70 in
Area (A) 125.00 in²
Weight 426 lb/ft

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 274,712 cm⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 475 mm deep, this section is common for floor beams, portal frame rafters, and columns in commercial and industrial buildings.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 4,984 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 274,712 cm⁴
Torsion St. Venant = GJ/L J = 13,777 cm⁴
Column buckling KL/r → Fcr r_x = 18.44 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — w360x634

Scenario: Commercial office floor — typical open-plan layout with raised floor. Simply supported wide flange, 10.9 m span, 2.4 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (16.8 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 7.2 × (10925)⁴ / (384 × 200000 × 2,747,120,000)

Δ_LL = 2.4 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 10925 / 300 = 36.4 mm

Step 3 — Dead + live deflection:

Δ_total = 5.7 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 4,486 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current CSA S16 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.