W530x124 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W21X83 per AISC A6. Approx. equivalent of W21X83. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 543.6 mm
Flange Width (bf) 212.3 mm
Flange Thickness (tf) 21.2 mm
Web Thickness (tw) 13.1 mm
Cross-Sectional Area (A) 157.4 cm²
Mass 123.5 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 76,170 3,388 cm⁴
Elastic Section Modulus (S) 2,802 320 cm³
Plastic Section Modulus (Z) 3,212 500 cm³
Radius of Gyration (r) 22.02 4.65 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 181 cm⁴
Warping Constant (Cw) 2,317,155 cm⁶
Distance Between Flange Centroids (ho) 52.32 cm
Effective Radius (rts) 5.61 cm

Imperial Reference

Property Value Unit
Depth (d) 21.40 in
Flange Width (bf) 8.36 in
Area (A) 24.40 in²
Weight 83 lb/ft

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 76,170 cm⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 543.6 mm deep and 123.5 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,124 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 76,170 cm⁴
Torsion St. Venant = GJ/L J = 181 cm⁴
Column buckling KL/r → Fcr r_x = 22.02 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — w530x124

Scenario: Commercial office floor — typical open-plan layout with raised floor. Simply supported wide flange, 14.1 m span, 2.4 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (16.8 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 7.2 × (14134)⁴ / (384 × 200000 × 761,700,000)

Δ_LL = 24.6 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 14134 / 300 = 47.1 mm

Step 3 — Dead + live deflection:

Δ_total = 57.3 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 1,012 kN·m. Also confirm shear resistance and bearing details at the supports.