W610x195 G40.21 350W — Canadian W-Shape Section Properties
Approximate equivalent of W24X131 per AISC A6. Approx. equivalent of W24X131. Verify against CISC Handbook.
Dimensions (Metric)
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 622.3 | mm |
| Flange Width (bf) | 327.7 | mm |
| Flange Thickness (tf) | 24.4 | mm |
| Web Thickness (tw) | 15.4 | mm |
| Cross-Sectional Area (A) | 249.1 | cmÃÂò |
| Mass | 194.9 | kg/m |
Elastic Section Properties (Metric)
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 167,324 | 14,152 | cm⁴ |
| Elastic Section Modulus (S) | 5,391 | 869 | cmÃÂó |
| Plastic Section Modulus (Z) | 6,063 | 1,336 | cmÃÂó |
| Radius of Gyration (r) | 25.91 | 7.54 | cm |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 395 | cm⁴ |
| Warping Constant (Cw) | 12,646,350 | cm⁶ |
| Distance Between Flange Centroids (ho) | 59.69 | cm |
| Effective Radius (rts) | 8.86 | cm |
Imperial Reference
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 24.50 | in |
| Flange Width (bf) | 12.90 | in |
| Area (A) | 38.60 | inÃÂò |
| Weight | 131 | lb/ft |
Section Profile Summary
Hot-rolled W-shape with Sx = 5,391 cm³. The section is suitable for primary framing in multi-storey buildings, crane girders, and bridge stringers.
At 622.3 mm deep and 194.9 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.
Key Design Checks (CSA S16)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 2,122 kNÃÂ÷m |
| Deflection | Δ = 5wL⁴/(384EIx) | Use Ix = 167,324 cm⁴ |
| Torsion | St. Venant = GJ/L | J = 395 cm⁴ |
| Column buckling | KL/r → Fcr | r_x = 25.91 cm |
Design Notes
- Compactness: Most W-shapes in ASTM A992 satisfy the compact limits in CSA S16 Table B4.1b for flexure (λ ≤ λp). This allows full plastic moment Mp development before local buckling occurs.
- Flange local buckling (FLB): The flange slenderness ratio bf/2tf is compared against λpf = 0.38√(E/Fy) ≈ 9.0 for compact sections.
- Web local buckling (WLB): h/tw is checked against λpw = 3.76√(E/Fy) ≈ 72 for flexure, and a more restrictive limit for uniform compression.
- Lateral-torsional buckling (LTB): Lp ≈ 317.2 cm (plastic limit). For unbraced lengths ≤ Lp, the full plastic moment is available. Between Lp and Lr, linear interpolation per CSA S16 Eq. F2-2 applies.
Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Car park beam — w610x195
Scenario: Multi-storey car park — asphalt wearing surface included. Simply supported wide flange, 15.6 m span, 2.7 m tributary width. Service loads: 6.0 kPa dead + 2.5 kPa live (23.0 kN/m total).
Given:
- Span L = 15557 mm (15.6 m)
- Total service load w = 23.0 kN/m
- Live load portion w_L = 6.8 kN/m
- Section w610x195: Ix = 1673.2 × 10⁶ mm⁴, Sx = 5,391,000 mm³, Zx = 6,063,000 mm³
- Steel: fy = 350 MPa, E = 200,000 MPa
- Design moment resistance: φMn = 0.9 × Zx × fy = 1,910 kNÃÂ÷m
Step 1 — Live load deflection:
Δ_LL = 5 w_L L⁴ / (384 E Ix)
Δ_LL = 5 × 6.8 × (15557)⁴ / (384 × 200000 × 1,673,240,000)
Δ_LL = 15.4 mm
Step 2 — Deflection limit (L/300):
Δ_limit = L / 300 = 15557 / 300 = 51.9 mm
Step 3 — Dead + live deflection:
Δ_total = 52.3 mm
Step 4 — Design check:
✓ Live load deflection is within the L/300 limit.
Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 1,910 kNÃÂ÷m. Also confirm shear resistance and bearing details at the supports.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current CSA S16 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.