W690x192 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W27X129 per AISC A6. Approx. equivalent of W27X129. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 701.0 mm
Flange Width (bf) 254.0 mm
Flange Thickness (tf) 27.9 mm
Web Thickness (tw) 15.5 mm
Cross-Sectional Area (A) 243.9 cm²
Mass 192.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 198,125 7,659 cm⁴
Elastic Section Modulus (S) 5,654 603 cm³
Plastic Section Modulus (Z) 6,473 944 cm³
Radius of Gyration (r) 28.45 5.61 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 462 cm⁴
Warping Constant (Cw) 8,726,250 cm⁶
Distance Between Flange Centroids (ho) 67.31 cm
Effective Radius (rts) 6.76 cm

Imperial Reference

Property Value Unit
Depth (d) 27.60 in
Flange Width (bf) 10.00 in
Area (A) 37.80 in²
Weight 129 lb/ft

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 198,125 cm⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 701 mm deep and 192 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 2,266 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 198,125 cm⁴
Torsion St. Venant = GJ/L J = 462 cm⁴
Column buckling KL/r → Fcr r_x = 28.45 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Roof beam (flat roof) — w690x192

Scenario: Flat roof with services — allowance for mechanical units and drainage. Simply supported wide flange, 11.9 m span, 3.6 m tributary width. Service loads: 2.0 kPa dead + 1.5 kPa live (12.6 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 5.4 × (11917)⁴ / (384 × 200000 × 1,981,250,000)

Δ_LL = 3.6 mm

Step 2 — Deflection limit (L/250):

Δ_limit = L / 250 = 11917 / 250 = 47.7 mm

Step 3 — Dead + live deflection:

Δ_total = 8.4 mm

Step 4 — Design check:

✓ Live load deflection is within the L/250 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 2,039 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current CSA S16 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.