W690x265 G40.21 350W â Canadian W-Shape Section Properties
Approximate equivalent of W27X178 per AISC A6. Approx. equivalent of W27X178. Verify against CISC Handbook.
Dimensions (Metric)
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 706.1 | mm |
| Flange Width (bf) | 358.1 | mm |
| Flange Thickness (tf) | 30.2 | mm |
| Web Thickness (tw) | 18.4 | mm |
| Cross-Sectional Area (A) | 338.7 | cmÃÂÃÂÃÂò |
| Mass | 264.9 | kg/m |
Elastic Section Properties (Metric)
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 292,193 | 23,101 | cmÃÂâÃÂÃÂÃÂô |
| Elastic Section Modulus (S) | 8,275 | 1,291 | cmÃÂÃÂÃÂó |
| Plastic Section Modulus (Z) | 9,341 | 1,999 | cmÃÂÃÂÃÂó |
| Radius of Gyration (r) | 29.46 | 8.26 | cm |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 837 | cmÃÂâÃÂÃÂÃÂô |
| Warping Constant (Cw) | 26,420,400 | cmÃÂâÃÂÃÂÃÂö |
| Distance Between Flange Centroids (ho) | 67.56 | cm |
| Effective Radius (rts) | 9.73 | cm |
Imperial Reference
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 27.80 | in |
| Flange Width (bf) | 14.10 | in |
| Area (A) | 52.50 | inÃÂÃÂÃÂò |
| Weight | 178 | lb/ft |
Section Profile Summary
With Ix = 292,193 cmâÃÂô, this wide flange is suitable for long-span floor beams and transfer girders where stiffness controls the design.
At 706.1 mm deep and 264.9 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.
Key Design Checks (CSA S16)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx ÃÂàFy | 3,269 kNÃÂ÷m |
| Deflection | ÃÂà= 5wLâÃÂô/(384EIx) | Use Ix = 292,193 cmâÃÂô |
| Torsion | St. Venant = GJ/L | J = 837 cmâÃÂô |
| Column buckling | KL/r âÃÂàFcr | r_x = 29.46 cm |
Design Notes
- Compactness: Most W-shapes in ASTM A992 satisfy the compact limits in CSA S16 Table B4.1b for flexure (ÃÂû âÃÂä ÃÂûp). This allows full plastic moment Mp development before local buckling occurs.
- Flange local buckling (FLB): The flange slenderness ratio bf/2tf is compared against ÃÂûpf = 0.38âÃÂÃÂ(E/Fy) âÃÂà9.0 for compact sections.
- Web local buckling (WLB): h/tw is checked against ÃÂûpw = 3.76âÃÂÃÂ(E/Fy) âÃÂà72 for flexure, and a more restrictive limit for uniform compression.
- Lateral-torsional buckling (LTB): Lp âÃÂà347.5 cm (plastic limit). For unbraced lengths âÃÂä Lp, the full plastic moment is available. Between Lp and Lr, linear interpolation per CSA S16 Eq. F2-2 applies.
Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: School classroom beam — w690x265
Scenario: School building — tighter deflection limit for suspended ceiling integrity. Simply supported wide flange, 12.7 m span, 2.4 m tributary width. Service loads: 3.5 kPa dead + 3.0 kPa live (15.6 kN/m total).
Given:
- Span L = 12710 mm (12.7 m)
- Total service load w = 15.6 kN/m
- Live load portion w_L = 7.2 kN/m
- Section w690x265: Ix = 2921.9 ÃÂà10âÃÂö mmâÃÂô, Sx = 8,275,000 mmÃÂó, Zx = 9,341,000 mmÃÂó
- Steel: fy = 350 MPa, E = 200,000 MPa
- Design moment resistance: ÃÂÃÂMn = 0.9 ÃÂàZx ÃÂàfy = 2,942 kNÃÂ÷m
Step 1 — Live load deflection:
ÃÂÃÂ_LL = 5 w_L LâÃÂô / (384 E Ix)
ÃÂÃÂ_LL = 5 ÃÂà7.2 ÃÂà(12710)âÃÂô / (384 ÃÂà200000 ÃÂà2,921,930,000)
ÃÂÃÂ_LL = 4.2 mm
Step 2 — Deflection limit (L/360):
ÃÂÃÂ_limit = L / 360 = 12710 / 360 = 35.3 mm
Step 3 — Dead + live deflection:
ÃÂÃÂ_total = 9.1 mm
Step 4 — Design check:
âÃÂàLive load deflection is within the L/360 limit.
Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed ÃÂÃÂMn = 2,942 kNÃÂ÷m. Also confirm shear resistance and bearing details at the supports.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current CSA S16 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.