W690x350 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W27X235 per AISC A6. Approx. equivalent of W27X235. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 729.0 mm
Flange Width (bf) 360.7 mm
Flange Thickness (tf) 40.9 mm
Web Thickness (tw) 23.1 mm
Cross-Sectional Area (A) 447.8 cm²
Mass 349.7 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 403,743 32,008 cm⁴
Elastic Section Modulus (S) 11,094 1,770 cm³
Plastic Section Modulus (Z) 12,651 2,753 cm³
Radius of Gyration (r) 29.97 8.46 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 1,956 cm⁴
Warping Constant (Cw) 37,858,500 cm⁶
Distance Between Flange Centroids (ho) 68.83 cm
Effective Radius (rts) 9.96 cm

Imperial Reference

Property Value Unit
Depth (d) 28.70 in
Flange Width (bf) 14.20 in
Area (A) 69.40 in²
Weight 235 lb/ft

Section Profile Summary

Hot-rolled W-shape with Sx = 11,094 cm³. The section is a practical choice for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 729 mm deep and 349.7 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 4,428 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 403,743 cm⁴
Torsion St. Venant = GJ/L J = 1,956 cm⁴
Column buckling KL/r → Fcr r_x = 29.97 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Retail floor beam — w690x350

Scenario: Retail space — higher live load for public occupancy per EN 1991-1-1. Simply supported wide flange, 16.8 m span, 2.4 m tributary width. Service loads: 4.5 kPa dead + 5.0 kPa live (22.8 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 12.0 × (16767)⁴ / (384 × 200000 × 4,037,430,000)

Δ_LL = 15.3 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 16767 / 300 = 55.9 mm

Step 3 — Dead + live deflection:

Δ_total = 29.1 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 3,985 kN·m. Also confirm shear resistance and bearing details at the supports.