W760x220 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W30X148 per AISC A6. Approx. equivalent of W30X148. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 779.8 mm
Flange Width (bf) 266.7 mm
Flange Thickness (tf) 30.0 mm
Web Thickness (tw) 16.5 mm
Cross-Sectional Area (A) 281.3 cm²
Mass 220.2 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 278,042 9,448 cm⁴
Elastic Section Modulus (S) 7,145 710 cm³
Plastic Section Modulus (Z) 8,194 1,114 cm³
Radius of Gyration (r) 31.50 5.79 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 604 cm⁴
Warping Constant (Cw) 13,263,900 cm⁶
Distance Between Flange Centroids (ho) 74.93 cm
Effective Radius (rts) 7.04 cm

Imperial Reference

Property Value Unit
Depth (d) 30.70 in
Flange Width (bf) 10.50 in
Area (A) 43.60 in²
Weight 148 lb/ft

Section Profile Summary

With Ix = 278,042 cm⁴, this wide flange is commonly specified for long-span floor beams and transfer girders where stiffness controls the design.

At 779.8 mm deep and 220.2 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 2,868 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 278,042 cm⁴
Torsion St. Venant = GJ/L J = 604 cm⁴
Column buckling KL/r → Fcr r_x = 31.5 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital ward beam — w760x220

Scenario: Hospital ward — strict deflection limits for medical equipment and services. Simply supported wide flange, 15.6 m span, 2.1 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (14.7 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.3 × (15596)⁴ / (384 × 200000 × 2,780,420,000)

Δ_LL = 8.7 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 15596 / 360 = 43.3 mm

Step 3 — Dead + live deflection:

Δ_total = 20.4 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 2,581 kN·m. Also confirm shear resistance and bearing details at the supports.