W840x576 G40.21 350W — Canadian W-Shape Section Properties

Approximate equivalent of W33X387 per AISC A6. Approx. equivalent of W33X387. Verify against CISC Handbook.

Dimensions (Metric)

Property Value Unit
Depth (d) 914.4 mm
Flange Width (bf) 411.5 mm
Flange Thickness (tf) 57.9 mm
Web Thickness (tw) 32.0 mm
Cross-Sectional Area (A) 735.5 cm²
Mass 575.9 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 1,011,439 67,429 cm⁴
Elastic Section Modulus (S) 22,122 3,277 cm³
Plastic Section Modulus (Z) 25,564 5,113 cm³
Radius of Gyration (r) 37.08 9.58 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 6,160 cm⁴
Warping Constant (Cw) 123,241,500 cm⁶
Distance Between Flange Centroids (ho) 85.60 cm
Effective Radius (rts) 11.40 cm

Imperial Reference

Property Value Unit
Depth (d) 36.00 in
Flange Width (bf) 16.20 in
Area (A) 114.00 in²
Weight 387 lb/ft

Section Profile Summary

Hot-rolled W-shape with Sx = 22,122 cm³. The section is a practical choice for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 914.4 mm deep and 575.9 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (CSA S16)

Check Formula This Section
Plastic moment Mp = Zx × Fy 8,947 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1,011,439 cm⁴
Torsion St. Venant = GJ/L J = 6,160 cm⁴
Column buckling KL/r → Fcr r_x = 37.08 cm

Design Notes

Verification (CSA S16): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Car park beam — w840x576

Scenario: Multi-storey car park — asphalt wearing surface included. Simply supported wide flange, 21.9 m span, 2.7 m tributary width. Service loads: 6.0 kPa dead + 2.5 kPa live (23.0 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.8 × (21946)⁴ / (384 × 200000 × 10,114,390,000)

Δ_LL = 10.1 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 21946 / 300 = 73.2 mm

Step 3 — Dead + live deflection:

Δ_total = 34.3 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per CSA S16) does not exceed φMn = 8,053 kN·m. Also confirm shear resistance and bearing details at the supports.