HEA800 HEA — European Wide Flange Beam (Light) Section Properties

HEA800 is a European HEA (Wide Flange Beam (Light)) per EN 10365 (successor to DIN 1025 / EN 10034) hot-rolled structural steel section. Standard European HEA dimensions per EN 10365. Verify against ArcelorMittal / Tata Steel section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 790 mm
Flange Width (bf) 300 mm
Flange Thickness (tf) 28.0 mm
Web Thickness (tw) 14.0 mm
Cross-Sectional Area (A) 270.8 cm²
Mass 224.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (Y-Y) Weak Axis (Z-Z) Unit
Moment of Inertia (I) 290,116 12,617 cm⁴
Elastic Section Modulus (S) 7,345 841 cm³
Plastic Section Modulus (Z) 8,286 1,296 cm³
Radius of Gyration (i) 32.73 6.83 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 506 cm⁴
Distance Between Flange Centroids (ho) 76.20 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by EN 1993. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 290,116 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 790 mm deep and 224 kg/m, this is a heavy section for primary framing — transfer beams, long-span roof girders, and major bridge stringers.

Key Design Checks (EN 1993)

Check Formula This Section
Plastic moment Mp = Zx × Fy 2,942 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 290,116 cm⁴
Torsion St. Venant = GJ/L J = 506 cm⁴
Column buckling KL/r → Fcr r_x = 32.73 cm

Design Notes

Verification (EN 1993): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Industrial floor beam — hea800

Scenario: Light industrial floor — forklift traffic and storage considerations. Simply supported I-section, 15.8 m span, 3 m tributary width. Service loads: 5.0 kPa dead + 7.5 kPa live (37.5 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 22.5 × (15800)⁴ / (384 × 210000 × 2,901,160,000)

Δ_LL = 30.0 mm

Step 2 — Deflection limit (L/250):

Δ_limit = L / 250 = 15800 / 250 = 63.2 mm

Step 3 — Dead + live deflection:

Δ_total = 49.9 mm

Step 4 — Design check:

✓ Live load deflection is within the L/250 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per EN 1993) does not exceed φMn = 2,942 kN·m. Also confirm shear resistance and bearing details at the supports.