HEM180 HEM — European Wide Flange Beam (Heavy) Section Properties

HEM180 is a European HEM (Wide Flange Beam (Heavy)) per EN 10365 (successor to DIN 1025 / EN 10034) hot-rolled structural steel section. Standard European HEM dimensions per EN 10365. Verify against ArcelorMittal / Tata Steel section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 219 mm
Flange Width (bf) 256 mm
Flange Thickness (tf) 17.5 mm
Web Thickness (tw) 17.5 mm
Cross-Sectional Area (A) 121.8 cm²
Mass 88.9 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (Y-Y) Weak Axis (Z-Z) Unit
Moment of Inertia (I) 10,026 4,902 cm⁴
Elastic Section Modulus (S) 916 383 cm³
Plastic Section Modulus (Z) 1,051 588 cm³
Radius of Gyration (i) 9.07 6.34 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 124 cm⁴
Distance Between Flange Centroids (ho) 20.15 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by EN 1993. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 10,026 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 219 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (EN 1993)

Check Formula This Section
Plastic moment Mp = Zx × Fy 373 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 10,026 cm⁴
Torsion St. Venant = GJ/L J = 124 cm⁴
Column buckling KL/r → Fcr r_x = 9.07 cm

Design Notes

Verification (EN 1993): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital ward beam — hem180

Scenario: Hospital ward — strict deflection limits for medical equipment and services. Simply supported I-section, 4.2 m span, 2.1 m tributary width. Service loads: 4.0 kPa dead + 3.0 kPa live (14.7 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 6.3 × (4161)⁴ / (384 × 210000 × 100,260,000)

Δ_LL = 1.2 mm

Step 2 — Deflection limit (L/360):

Δ_limit = L / 360 = 4161 / 360 = 11.6 mm

Step 3 — Dead + live deflection:

Δ_total = 2.7 mm

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per EN 1993) does not exceed φMn = 373 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current EN 1993 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.