HEM280 HEM — European Wide Flange Beam (Heavy) Section Properties

HEM280 is a European HEM (Wide Flange Beam (Heavy)) per EN 10365 (successor to DIN 1025 / EN 10034) hot-rolled structural steel section. Standard European HEM dimensions per EN 10365. Verify against ArcelorMittal / Tata Steel section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 310 mm
Flange Width (bf) 288 mm
Flange Thickness (tf) 33.0 mm
Web Thickness (tw) 18.5 mm
Cross-Sectional Area (A) 235.2 cm²
Mass 189.0 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (Y-Y) Weak Axis (Z-Z) Unit
Moment of Inertia (I) 38,874 13,151 cm⁴
Elastic Section Modulus (S) 2,508 913 cm³
Plastic Section Modulus (Z) 2,908 1,389 cm³
Radius of Gyration (i) 12.86 7.48 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 741 cm⁴
Distance Between Flange Centroids (ho) 27.70 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by EN 1993. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 38,874 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 310 mm deep, this section is common for floor beams, portal frame rafters, and columns in commercial and industrial buildings.

Key Design Checks (EN 1993)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,032 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 38,874 cm⁴
Torsion St. Venant = GJ/L J = 741 cm⁴
Column buckling KL/r → Fcr r_x = 12.86 cm

Design Notes

Verification (EN 1993): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Retail floor beam — hem280

Scenario: Retail space — higher live load for public occupancy per EN 1991-1-1. Simply supported I-section, 6.8 m span, 2.4 m tributary width. Service loads: 4.5 kPa dead + 5.0 kPa live (22.8 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 12.0 × (6820)⁴ / (384 × 210000 × 388,740,000)

Δ_LL = 4.1 mm

Step 2 — Deflection limit (L/300):

Δ_limit = L / 300 = 6820 / 300 = 22.7 mm

Step 3 — Dead + live deflection:

Δ_total = 7.9 mm

Step 4 — Design check:

✓ Live load deflection is within the L/300 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per EN 1993) does not exceed φMn = 1,032 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current EN 1993 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.