IPE200 IPE — European I-Section Section Properties

IPE200 is a European IPE (I-Section) per EN 10365 (successor to DIN 1025 / EN 10034) hot-rolled structural steel section. Standard European IPE dimensions per EN 10365. Verify against ArcelorMittal / Tata Steel section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 200 mm
Flange Width (bf) 100 mm
Flange Thickness (tf) 8.5 mm
Web Thickness (tw) 5.6 mm
Cross-Sectional Area (A) 27.3 cm²
Mass 22.4 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (Y-Y) Weak Axis (Z-Z) Unit
Moment of Inertia (I) 1,846 142 cm⁴
Elastic Section Modulus (S) 185 28 cm³
Plastic Section Modulus (Z) 210 44 cm³
Radius of Gyration (i) 8.23 2.28 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 5 cm⁴
Distance Between Flange Centroids (ho) 19.15 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by EN 1993. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 1,846 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 200 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (EN 1993)

Check Formula This Section
Plastic moment Mp = Zx × Fy 75 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1,846 cm⁴
Torsion St. Venant = GJ/L J = 5 cm⁴
Column buckling KL/r → Fcr r_x = 8.23 cm

Design Notes

Verification (EN 1993): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Roof beam (flat roof) — ipe200

Scenario: Flat roof with services — allowance for mechanical units and drainage. Simply supported I-section, 3.8 m span, 3.6 m tributary width. Service loads: 2.0 kPa dead + 1.5 kPa live (12.6 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 5.4 × (3800)⁴ / (384 × 210000 × 18,460,000)

Δ_LL = 3.8 mm

Step 2 — Deflection limit (L/250):

Δ_limit = L / 250 = 3800 / 250 = 15.2 mm

Step 3 — Dead + live deflection:

Δ_total = 8.8 mm

Step 4 — Design check:

✓ Live load deflection is within the L/250 limit.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per EN 1993) does not exceed φMn = 75 kN·m. Also confirm shear resistance and bearing details at the supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current EN 1993 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.