IPE300 IPE — European I-Section Section Properties

IPE300 is a European IPE (I-Section) per EN 10365 (successor to DIN 1025 / EN 10034) hot-rolled structural steel section. Standard European IPE dimensions per EN 10365. Verify against ArcelorMittal / Tata Steel section catalog.

Dimensions (Metric)

Property Value Unit
Depth (d) 300 mm
Flange Width (bf) 150 mm
Flange Thickness (tf) 10.7 mm
Web Thickness (tw) 7.1 mm
Cross-Sectional Area (A) 51.9 cm²
Mass 42.2 kg/m

Elastic Section Properties (Metric)

Property Strong Axis (Y-Y) Weak Axis (Z-Z) Unit
Moment of Inertia (I) 7,999 603 cm⁴
Elastic Section Modulus (S) 533 80 cm³
Plastic Section Modulus (Z) 602 124 cm³
Radius of Gyration (i) 12.42 3.41 cm

Torsional Properties

Property Value Unit
Torsional Constant (J) 16 cm⁴
Distance Between Flange Centroids (ho) 28.93 cm

Section Profile Summary

This is a standard hot-rolled I-section profile covered by EN 1993. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 7,999 cm⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 300 mm deep, this is a mid-range section for secondary beams, roof purlins, and bracing in standard framing.

Key Design Checks (EN 1993)

Check Formula This Section
Plastic moment Mp = Zx × Fy 214 kN·m
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 7,999 cm⁴
Torsion St. Venant = GJ/L J = 16 cm⁴
Column buckling KL/r → Fcr r_x = 12.42 cm

Design Notes

Verification (EN 1993): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Industrial floor beam — ipe300

Scenario: Light industrial floor — forklift traffic and storage considerations. Simply supported I-section, 7.5 m span, 3 m tributary width. Service loads: 5.0 kPa dead + 7.5 kPa live (37.5 kN/m total).

Given:

Step 1 — Live load deflection:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × 22.5 × (7500)⁴ / (384 × 210000 × 79,990,000)

Δ_LL = 55.2 mm

Step 2 — Deflection limit (L/250):

Δ_limit = L / 250 = 7500 / 250 = 30.0 mm

Step 3 — Dead + live deflection:

Δ_total = 92.0 mm

Step 4 — Design check:

⚠ Live load deflection exceeds L/250 — consider a deeper section, reduce tributary, or shorten the span.

Verify the design moment M*_Ed (from factored loads 1.35G + 1.5Q per EN 1993) does not exceed φMn = 214 kN·m. Also confirm shear resistance and bearing details at the supports.