C10X25 Steel C-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 10 254.0 mm
Flange Width (bf) 2.89 7.34 cm
Flange Thickness (tf) 0.436 11.1 mm
Web Thickness (tw) 0.526 13.4 mm
Area (A) 7.35 in² 47.4 cm²
Weight 25 lb/ft 37.2 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 91.1 3.34 in⁴
Elastic Section Modulus (S) 18.2 1.47 in³
Plastic Section Modulus (Z) 23.1 3.18 in³
Radius of Gyration (r) 3.52 0.675 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.687 in⁴
Warping Constant (Cw) 68.3 in⁶
Distance Between Flange Centroids (ho) 9.56 in
Effective Radius (rts) 0.911 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 10" deep, this is a compact section appropriate for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,155 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 91.1 in⁴
Torsion St. Venant = GJ/L J = 0.687 in⁴
Column buckling KL/r → Fcr r_x = 3.52 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Laboratory floor beam — c10x25

Scenario: Laboratory floor with heavy equipment allowance — vibration sensitive. Simply supported channel, 21 ft span, 7 ft tributary width. Service loads: 60 psf dead + 80 psf live (980 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (560/12) × (252)⁴ / (384 × 29,000,000 × 91.1)

Δ_LL = 0.93 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 252 / 240 = 1.05 in

Step 3 — Dead + live deflection:

Δ_total = 1.62 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 87 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.