C3X5 Steel C-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 3 76.2 mm
Flange Width (bf) 1.5 3.81 cm
Flange Thickness (tf) 0.273 6.9 mm
Web Thickness (tw) 0.258 6.6 mm
Area (A) 1.47 in² 9.5 cm²
Weight 5 lb/ft 7.4 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 1.85 0.241 in⁴
Elastic Section Modulus (S) 1.23 0.228 in³
Plastic Section Modulus (Z) 1.52 0.464 in³
Radius of Gyration (r) 1.12 0.405 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.043 in⁴
Warping Constant (Cw) 0.379 in⁶
Distance Between Flange Centroids (ho) 2.73 in
Effective Radius (rts) 0.496 in

Section Profile Summary

Channels are efficient for bracing, girts, and stair stringers where loads align near the shear center. At 5 lb/ft, this channel is appropriate for secondary framing in industrial and commercial structures.

At 3" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 76 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1.85 in⁴
Torsion St. Venant = GJ/L J = 0.043 in⁴
Column buckling KL/r → Fcr r_x = 1.12 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Roof beam (flat roof) — c3x5

Scenario: Flat roof beam with mechanical unit allowance — drainage slope not included. Simply supported channel, 10 ft span, 6 ft tributary width. Service loads: 25 psf dead + 20 psf live (270 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (120/12) × (120)⁴ / (384 × 29,000,000 × 1.85)

Δ_LL = 0.50 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 1.13 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 6 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.