C4X5.4 Steel C-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 4 101.6 mm
Flange Width (bf) 1.58 4.01 cm
Flange Thickness (tf) 0.296 7.5 mm
Web Thickness (tw) 0.184 4.7 mm
Area (A) 1.58 in² 10.2 cm²
Weight 5.4 lb/ft 8.0 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 3.85 0.312 in⁴
Elastic Section Modulus (S) 1.92 0.277 in³
Plastic Section Modulus (Z) 2.29 0.565 in³
Radius of Gyration (r) 1.56 0.444 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.04 in⁴
Warping Constant (Cw) 0.921 in⁶
Distance Between Flange Centroids (ho) 3.7 in
Effective Radius (rts) 0.528 in

Section Profile Summary

Channels are efficient for bracing, girts, and stair stringers where loads align near the shear center. At 5.4 lb/ft, this channel is well-suited for secondary framing in industrial and commercial structures.

At 4" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 114.5 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 3.85 in⁴
Torsion St. Venant = GJ/L J = 0.04 in⁴
Column buckling KL/r → Fcr r_x = 1.56 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — c4x5_4

Scenario: Office floor in a commercial building — typical open-plan layout. Simply supported channel, 10 ft span, 8 ft tributary width. Service loads: 50 psf dead + 50 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (120)⁴ / (384 × 29,000,000 × 3.85)

Δ_LL = 0.81 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 1.61 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 9 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.