C5X6.7 Steel C-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 5 127.0 mm
Flange Width (bf) 1.75 4.45 cm
Flange Thickness (tf) 0.32 8.1 mm
Web Thickness (tw) 0.19 4.8 mm
Area (A) 1.97 in² 12.7 cm²
Weight 6.7 lb/ft 10.0 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 7.48 0.47 in⁴
Elastic Section Modulus (S) 2.99 0.372 in³
Plastic Section Modulus (Z) 3.55 0.757 in³
Radius of Gyration (r) 1.95 0.489 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.055 in⁴
Warping Constant (Cw) 2.22 in⁶
Distance Between Flange Centroids (ho) 4.68 in
Effective Radius (rts) 0.584 in

Section Profile Summary

The shear center of a channel lies outside the web (distance e₀ from the web face). Loads applied to the top flange produce torsion unless the load plane passes through the shear center. For AISC 360 flexural design, lateral-torsional buckling must be checked with the warping constant Cw.

At 5" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 177.5 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 7.48 in⁴
Torsion St. Venant = GJ/L J = 0.055 in⁴
Column buckling KL/r → Fcr r_x = 1.95 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — c5x6_7

Scenario: Office floor in a commercial building — typical open-plan layout. Simply supported channel, 11 ft span, 8 ft tributary width. Service loads: 50 psf dead + 50 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (132)⁴ / (384 × 29,000,000 × 7.48)

Δ_LL = 0.61 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 132 / 240 = 0.55 in

Step 3 — Dead + live deflection:

Δ_total = 1.21 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 13 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.