HP18X181 Steel HP-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 18 457.2 mm
Flange Width (bf) 18 45.72 cm
Flange Thickness (tf) 1 25.4 mm
Web Thickness (tw) 1 25.4 mm
Area (A) 53.2 in² 343.2 cm²
Weight 181 lb/ft 269.4 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 3020 974 in⁴
Elastic Section Modulus (S) 336 108 in³
Plastic Section Modulus (Z) 379 167 in³
Radius of Gyration (r) 7.53 4.28 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 20.7 in⁴
Warping Constant (Cw) 70400 in⁶
Distance Between Flange Centroids (ho) 17 in
Effective Radius (rts) 4.96 in

Section Profile Summary

This is a standard hot-rolled bearing pile profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 3,020 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 18" deep and 181 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 18,950 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 3,020 in⁴
Torsion St. Venant = GJ/L J = 20.7 in⁴
Column buckling KL/r → Fcr r_x = 7.53 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Bearing Pile Capacity — hp18x181

Scenario: hp18x181 driven to 60 ft depth in medium-dense sand. The pile carries axial compression from a column above. Pile capacity is governed by a combination of geotechnical end bearing + skin friction, plus the structural section capacity.

Given:

Structural capacity (AISC 360 Chapter E):

φPn = 0.9 × Fy × Ag = 0.9 × 50 × 53.2 = 2,394 kips

The structural capacity typically governs over geotechnical capacity for HP sections in dense soils. Driving stresses should also be checked per PDCA/AASHTO specifications — limit driving stress to 0.9Fy during hard driving conditions.

The final pile capacity must be confirmed by a geotechnical engineer based on site-specific soil conditions, PDA testing, and pile driving records. The structural capacity above is a preliminary estimate only.