HSS10.750X0.625 Steel Round HSS — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Outer Diameter (OD) | 10.8 | 274.3 mm |
| Wall Thickness (t) | 0.625 | 15.9 mm |
| Area (A) | 18.6 in² | 120.0 cmÃÂò |
| Weight | 67.65 lb/ft | 100.7 kg/m |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 241 | 241 | in⁴ |
| Elastic Section Modulus (S) | 44.8 | 44.8 | in³ |
| Plastic Section Modulus (Z) | 60.2 | 60.2 | in³ |
| Radius of Gyration (r) | 3.6 | 3.6 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 482 | in⁴ |
| Warping Constant (Cw) | 0 | in⁶ |
Section Profile Summary
HSS provides uniform strength in all directions — efficient for columns, bracing, and torsion-critical applications. At 67.65 lb/ft, this section is commonly specified for bracing, secondary columns, and architectural exposed steel.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 3,010 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 241 in⁴ |
| Torsion | St. Venant = GJ/L | J = 482 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 3.6 in |
Design Notes
- Wall slenderness: b/t limits per AISC 360 Table B4.1a define compact, noncompact, and slender classifications. Round HSS use D/t limits.
- HSS connection design: Welded connections to HSS walls must check chord plastification, punching shear, and sidewall yielding per AISC 360 Chapter K. Through-bolting requires reinforcing sleeves or plate washers.
- Concrete-filled HSS: For composite column applications, filling the HSS with concrete increases axial capacity and fire resistance. Composite design follows AISC 360 Chapter I.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Column Capacity — hss10_750x0_625
Scenario: Interior column in a 3-story braced frame office building Unbraced length L = 11 ft.
Given:
- hss10_750x0_625: Ag = 18.6 in²
- r_min = 3.6 in (governing radius of gyration)
- Steel: ASTM A500 Gr. C, Fy = 50 ksi, E = 29,000 ksi
- Effective length factor K = 1.0 (pinned-pinned)
Step 1 — Slenderness ratio:
KL/r = 132 / 3.6 = 37
Step 2 — Determine critical stress Fcr (AISC 360 Chapter E):
Elastic buckling stress: Fe = ÃÂÃÂÃÂòE / (KL/r)ÃÂò = ÃÂÃÂÃÂò × 29,000 / (37)ÃÂò = 209 ksi
For HSS with KL/r âÃÂä 4.71âÃÂÃÂ(E/Fy) = 4.71âÃÂÃÂ(29,000/50) = 113.4:
If KL/r âÃÂä 113.4: Fcr = 0.658^(Fy/Fe) × Fy (inelastic buckling) If KL/r > 113.4: Fcr = 0.877Fe (elastic buckling)
Step 3 — Design compressive strength:
φPn = φ × Fcr × Ag = 0.9 × Fcr × 18.6 âÃÂà837 kips (preliminary)
For a precise capacity accounting for local buckling and the exact KL/r value, use the Column Capacity Calculator with this section's properties.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.