HSS2-1/2X1X3/16 Steel Rectangular HSS — Section Properties

Dimensions

Property Value Unit
Height (h) 2.5 63.5 mm
Width (w) 1 25.4 mm
Wall Thickness (t) 0.188 4.8 mm
Area (A) 1.02 in² 6.6 cm²
Weight 3.68 lb/ft 5.5 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 0.646 0.143 in⁴
Elastic Section Modulus (S) 0.517 0.285 in³
Plastic Section Modulus (Z) 0.713 0.36 in³
Radius of Gyration (r) 0.796 0.374 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.412 in⁴
Warping Constant (Cw) 0 in⁶

Section Profile Summary

The closed shape eliminates the weak-axis buckling concern that governs open sections. Torsional constant J = 0.412 in⁴ is typically an order of magnitude higher than a W-shape of similar weight, making HSS the go-to choice when torsion cannot be avoided.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 35.65 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 0.646 in⁴
Torsion St. Venant = GJ/L J = 0.412 in⁴
Column buckling KL/r → Fcr r_x = 0.796 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Column Capacity — hss2-1-2x1x3-16

Scenario: Wind column between windows in a curtain wall system Unbraced length L = 13 ft.

Given:

Step 1 — Slenderness ratio:

KL/r = 156 / 0.796 = 196

Step 2 — Determine critical stress Fcr (AISC 360 Chapter E):

Elastic buckling stress: Fe = π²E / (KL/r)² = π² × 29,000 / (196)² = 7 ksi

For HSS with KL/r ≤ 4.71√(E/Fy) = 4.71√(29,000/50) = 113.4:

If KL/r ≤ 113.4: Fcr = 0.658^(Fy/Fe) × Fy (inelastic buckling) If KL/r > 113.4: Fcr = 0.877Fe (elastic buckling)

Step 3 — Design compressive strength:

φPn = φ × Fcr × Ag = 0.9 × Fcr × 1.02 ≈ 46 kips (preliminary)

For a precise capacity accounting for local buckling and the exact KL/r value, use the Column Capacity Calculator with this section's properties.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.