HSS20X16X5/8 Steel Rectangular HSS — Section Properties

Dimensions

Property Value Unit
Height (h) 20 508.0 mm
Width (w) 16 406.4 mm
Wall Thickness (t) 0.625 15.9 mm
Area (A) 39.6 in² 255.5 cm²
Weight 144.4 lb/ft 214.9 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 2320 1640 in⁴
Elastic Section Modulus (S) 232 206 in³
Plastic Section Modulus (Z) 275 236 in³
Radius of Gyration (r) 7.65 6.44 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 3040 in⁴
Warping Constant (Cw) 0 in⁶

Section Profile Summary

The closed shape eliminates the weak-axis buckling concern that governs open sections. Torsional constant J = 3,040 in⁴ is typically an order of magnitude higher than a W-shape of similar weight, making HSS the go-to choice when torsion cannot be avoided.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 13,750 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 2,320 in⁴
Torsion St. Venant = GJ/L J = 3,040 in⁴
Column buckling KL/r → Fcr r_x = 7.65 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Column Capacity — hss20x16x5-8

Scenario: Interior column in a 3-story braced frame office building Unbraced length L = 11 ft.

Given:

Step 1 — Slenderness ratio:

KL/r = 132 / 7.65 = 17

Step 2 — Determine critical stress Fcr (AISC 360 Chapter E):

Elastic buckling stress: Fe = π²E / (KL/r)² = π² × 29,000 / (17)² = 990 ksi

For HSS with KL/r ≤ 4.71√(E/Fy) = 4.71√(29,000/50) = 113.4:

If KL/r ≤ 113.4: Fcr = 0.658^(Fy/Fe) × Fy (inelastic buckling) If KL/r > 113.4: Fcr = 0.877Fe (elastic buckling)

Step 3 — Design compressive strength:

φPn = φ × Fcr × Ag = 0.9 × Fcr × 39.6 ≈ 1,782 kips (preliminary)

For a precise capacity accounting for local buckling and the exact KL/r value, use the Column Capacity Calculator with this section's properties.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.