HSS28.000X0.750 Steel Round HSS — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Outer Diameter (OD) | 28 | 711.2 mm |
| Wall Thickness (t) | 0.75 | 19.0 mm |
| Area (A) | 59.8 in² | 385.8 cmÃÂò |
| Weight | 218.5 lb/ft | 325.2 kg/m |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 5580 | 5580 | in⁴ |
| Elastic Section Modulus (S) | 398 | 398 | in³ |
| Plastic Section Modulus (Z) | 520 | 520 | in³ |
| Radius of Gyration (r) | 9.66 | 9.66 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 11200 | in⁴ |
| Warping Constant (Cw) | 0 | in⁶ |
Section Profile Summary
Closed tubular section with J = 11,200 in⁴ — torsional stiffness is significantly higher than an open section of equivalent weight. The flat faces accept welded gusset and end-plate connections without stiffeners.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 26,000 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 5,580 in⁴ |
| Torsion | St. Venant = GJ/L | J = 11,200 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 9.66 in |
Design Notes
- Wall slenderness: b/t limits per AISC 360 Table B4.1a define compact, noncompact, and slender classifications. Round HSS use D/t limits.
- HSS connection design: Welded connections to HSS walls must check chord plastification, punching shear, and sidewall yielding per AISC 360 Chapter K. Through-bolting requires reinforcing sleeves or plate washers.
- Concrete-filled HSS: For composite column applications, filling the HSS with concrete increases axial capacity and fire resistance. Composite design follows AISC 360 Chapter I.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Column Capacity — hss28_000x0_750
Scenario: Canopy support column Unbraced length L = 12 ft.
Given:
- hss28_000x0_750: Ag = 59.8 in²
- r_min = 9.66 in (governing radius of gyration)
- Steel: ASTM A500 Gr. C, Fy = 50 ksi, E = 29,000 ksi
- Effective length factor K = 2.1 (cantilever, fixed base)
Step 1 — Slenderness ratio:
KL/r = 144 / 9.66 = 15
Step 2 — Determine critical stress Fcr (AISC 360 Chapter E):
Elastic buckling stress: Fe = ÃÂÃÂÃÂòE / (KL/r)ÃÂò = ÃÂÃÂÃÂò × 29,000 / (15)ÃÂò = 1,272 ksi
For HSS with KL/r âÃÂä 4.71âÃÂÃÂ(E/Fy) = 4.71âÃÂÃÂ(29,000/50) = 113.4:
If KL/r âÃÂä 113.4: Fcr = 0.658^(Fy/Fe) × Fy (inelastic buckling) If KL/r > 113.4: Fcr = 0.877Fe (elastic buckling)
Step 3 — Design compressive strength:
φPn = φ × Fcr × Ag = 0.9 × Fcr × 59.8 âÃÂà2,691 kips (preliminary)
For a precise capacity accounting for local buckling and the exact KL/r value, use the Column Capacity Calculator with this section's properties.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.