Dimensions

Property Value Unit
Depth (d) 10 254.0 mm
Flange Width (bf) 3.32 8.43 cm
Flange Thickness (tf) 0.575 14.6 mm
Web Thickness (tw) 0.29 7.4 mm
Area (A) 6.45 in² 41.6 cm²
Weight 22 lb/ft 32.7 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 102 6.4 in⁴
Elastic Section Modulus (S) 20.5 2.75 in³
Plastic Section Modulus (Z) 23.9 5.29 in³
Radius of Gyration (r) 3.99 0.997 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.51 in⁴
Warping Constant (Cw) 110 in⁶
Distance Between Flange Centroids (ho) 9.43 in
Effective Radius (rts) 1.14 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 10" deep, this is a compact section a practical choice for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,195 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 102 in⁴
Torsion St. Venant = GJ/L J = 0.51 in⁴
Column buckling KL/r → Fcr r_x = 3.99 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Assembly hall floor beam — mc10x22

Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported channel, 19 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (800/12) × (228)⁴ / (384 × 29,000,000 × 102)

Δ_LL = 0.79 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 228 / 240 = 0.95 in

Step 3 — Dead + live deflection:

Δ_total = 1.27 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 90 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.