MC12X14.3 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 12 304.8 mm
Flange Width (bf) 2.12 5.38 cm
Flange Thickness (tf) 0.313 8.0 mm
Web Thickness (tw) 0.25 6.3 mm
Area (A) 4.18 in² 27.0 cm²
Weight 14.3 lb/ft 21.3 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 76.1 1 in⁴
Elastic Section Modulus (S) 12.7 0.574 in³
Plastic Section Modulus (Z) 15.9 1.21 in³
Radius of Gyration (r) 4.27 0.489 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.117 in⁴
Warping Constant (Cw) 32.8 in⁶
Distance Between Flange Centroids (ho) 11.7 in
Effective Radius (rts) 0.672 in

Section Profile Summary

Channels are efficient for bracing, girts, and stair stringers where loads align near the shear center. At 14.3 lb/ft, this channel is a practical choice for secondary framing in industrial and commercial structures.

At 12" deep, this is a compact section a practical choice for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 795 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 76.1 in⁴
Torsion St. Venant = GJ/L J = 0.117 in⁴
Column buckling KL/r → Fcr r_x = 4.27 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Library stack beam — mc12x14_3

Scenario: Library stack area — dead load includes shelving and books. Simply supported channel, 20 ft span, 7 ft tributary width. Service loads: 85 psf dead + 60 psf live (1015 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (420/12) × (240)⁴ / (384 × 29,000,000 × 76.1)

Δ_LL = 0.69 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 240 / 240 = 1.00 in

Step 3 — Dead + live deflection:

Δ_total = 1.66 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 60 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.