MC12X45 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 12 304.8 mm
Flange Width (bf) 4.01 10.19 cm
Flange Thickness (tf) 0.7 17.8 mm
Web Thickness (tw) 0.71 18.0 mm
Area (A) 13.2 in² 85.2 cm²
Weight 45 lb/ft 67.0 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 251 15.8 in⁴
Elastic Section Modulus (S) 41.9 5.3 in³
Plastic Section Modulus (Z) 52 10.1 in³
Radius of Gyration (r) 4.36 1.09 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 2.33 in⁴
Warping Constant (Cw) 373 in⁶
Distance Between Flange Centroids (ho) 11.3 in
Effective Radius (rts) 1.35 in

Section Profile Summary

The shear center of a channel lies outside the web (distance e₀ from the web face). Loads applied to the top flange produce torsion unless the load plane passes through the shear center. For AISC 360 flexural design, lateral-torsional buckling must be checked with the warping constant Cw.

At 12" deep, this is a compact section appropriate for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 2,600 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 251 in⁴
Torsion St. Venant = GJ/L J = 2.33 in⁴
Column buckling KL/r → Fcr r_x = 4.36 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Roof beam (flat roof) — mc12x45

Scenario: Flat roof beam with mechanical unit allowance — drainage slope not included. Simply supported channel, 23 ft span, 6 ft tributary width. Service loads: 25 psf dead + 20 psf live (270 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (120/12) × (276)⁴ / (384 × 29,000,000 × 251)

Δ_LL = 0.10 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 276 / 240 = 1.15 in

Step 3 — Dead + live deflection:

Δ_total = 0.23 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 195 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.