MC13X35 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 13 330.2 mm
Flange Width (bf) 4.07 10.34 cm
Flange Thickness (tf) 0.61 15.5 mm
Web Thickness (tw) 0.447 11.4 mm
Area (A) 10.3 in² 66.5 cm²
Weight 35 lb/ft 52.1 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 252 12.3 in⁴
Elastic Section Modulus (S) 38.8 3.97 in³
Plastic Section Modulus (Z) 46.5 8.04 in³
Radius of Gyration (r) 4.95 1.09 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 1.13 in⁴
Warping Constant (Cw) 412 in⁶
Distance Between Flange Centroids (ho) 12.4 in
Effective Radius (rts) 1.35 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 13" deep and 35 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 2,325 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 252 in⁴
Torsion St. Venant = GJ/L J = 1.13 in⁴
Column buckling KL/r → Fcr r_x = 4.95 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Assembly hall floor beam — mc13x35

Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported channel, 29 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (800/12) × (348)⁴ / (384 × 29,000,000 × 252)

Δ_LL = 1.74 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 348 / 240 = 1.45 in

Step 3 — Dead + live deflection:

Δ_total = 2.79 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 174 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.