MC3X7.1 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 3 76.2 mm
Flange Width (bf) 1.94 4.93 cm
Flange Thickness (tf) 0.351 8.9 mm
Web Thickness (tw) 0.312 7.9 mm
Area (A) 2.11 in² 13.6 cm²
Weight 7.1 lb/ft 10.6 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 2.72 0.666 in⁴
Elastic Section Modulus (S) 1.81 0.518 in³
Plastic Section Modulus (Z) 2.24 0.998 in³
Radius of Gyration (r) 1.14 0.562 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.093 in⁴
Warping Constant (Cw) 0.915 in⁶
Distance Between Flange Centroids (ho) 2.65 in
Effective Radius (rts) 0.657 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 3" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 112 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 2.72 in⁴
Torsion St. Venant = GJ/L J = 0.093 in⁴
Column buckling KL/r → Fcr r_x = 1.14 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Laboratory floor beam — mc3x7_1

Scenario: Laboratory floor with heavy equipment allowance — vibration sensitive. Simply supported channel, 10 ft span, 7 ft tributary width. Service loads: 60 psf dead + 80 psf live (980 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (560/12) × (120)⁴ / (384 × 29,000,000 × 2.72)

Δ_LL = 1.60 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 2.80 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 8 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.