MT5X3.75 Steel MT-shape — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 5 | 127.0 mm |
| Flange Width (bf) | 2.69 | 6.83 cm |
| Flange Thickness (tf) | 0.173 | 4.4 mm |
| Web Thickness (tw) | 0.13 | 3.3 mm |
| Area (A) | 1.11 in² | 7.2 cmÃÂò |
| Weight | 3.75 lb/ft | 5.6 kg/m |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 2.91 | 0.281 | in⁴ |
| Elastic Section Modulus (S) | 0.836 | 0.209 | in³ |
| Plastic Section Modulus (Z) | 1.51 | 0.334 | in³ |
| Radius of Gyration (r) | 1.63 | 0.505 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 0.009 | in⁴ |
| Warping Constant (Cw) | 0.008 | in⁶ |
Section Profile Summary
This is a standard hot-rolled section profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 2.91 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.
At 5" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 75.5 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 2.91 in⁴ |
| Torsion | St. Venant = GJ/L | J = 0.009 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 1.63 in |
Design Notes
- Compactness: Verify flange and web slenderness against AISC 360 Table B4.1 classification limits for the governing load case (pure compression, pure flexure, or combined).
- Combined loading: For members under simultaneous axial force and bending, use the interaction equations in AISC 360 Section H. The governing equation depends on the ratio of required to available axial strength.
- Connection limit states: Check bolt bearing, tear-out, block shear, and weld strength at all connections. The governing connection limit state often controls the member size selection.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.