S4X7.7 Steel S-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 4 101.6 mm
Flange Width (bf) 2.66 6.76 cm
Flange Thickness (tf) 0.293 7.4 mm
Web Thickness (tw) 0.193 4.9 mm
Area (A) 2.26 in² 14.6 cm²
Weight 7.7 lb/ft 11.5 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 6.05 0.748 in⁴
Elastic Section Modulus (S) 3.03 0.562 in³
Plastic Section Modulus (Z) 3.5 0.97 in³
Radius of Gyration (r) 1.64 0.576 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.073 in⁴
Warping Constant (Cw) 2.57 in⁶
Distance Between Flange Centroids (ho) 3.71 in
Effective Radius (rts) 0.676 in

Section Profile Summary

This is a standard hot-rolled I-beam profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 6.05 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 4" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 175 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 6.05 in⁴
Torsion St. Venant = GJ/L J = 0.073 in⁴
Column buckling KL/r → Fcr r_x = 1.64 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Warehouse mezzanine beam — s4x7_7

Scenario: Mezzanine beam in a warehouse — storage live load governs design. Simply supported I-beam, 10 ft span, 5 ft tributary width. Service loads: 30 psf dead + 125 psf live (775 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (625/12) × (120)⁴ / (384 × 29,000,000 × 6.05)

Δ_LL = 0.80 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 0.99 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 13 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.