ST7.5X25 Steel ST-shape — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 7.5 | 190.5 mm |
| Flange Width (bf) | 5.64 | 14.33 cm |
| Flange Thickness (tf) | 0.622 | 15.8 mm |
| Web Thickness (tw) | 0.55 | 14.0 mm |
| Area (A) | 7.34 in² | 47.4 cmÃÂò |
| Weight | 25 lb/ft | 37.2 kg/m |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 40.5 | 7.79 | in⁴ |
| Elastic Section Modulus (S) | 7.72 | 2.76 | in³ |
| Plastic Section Modulus (Z) | 14 | 4.99 | in³ |
| Radius of Gyration (r) | 2.35 | 1.03 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 1.05 | in⁴ |
| Warping Constant (Cw) | 2.02 | in⁶ |
Section Profile Summary
WT/ST sections are cut from W-shapes — the stem tip was at the mid-depth of the original beam and has the highest residual stresses. For beam applications, orient the stem in tension (pointing down for simply-supported beams). Per AISC 360 Section F9, the flexural capacity depends on whether the stem or flange is in compression.
At 7.5" deep, this is a compact section commonly specified for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 700 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 40.5 in⁴ |
| Torsion | St. Venant = GJ/L | J = 1.05 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 2.35 in |
Design Notes
- Stem in tension for beams: Orient the tee so the flange is in compression (stem down for gravity loads). Per AISC 360 Section F9, the flexural capacity is significantly higher with the stem in tension.
- Flexural-torsional buckling for columns: Single-axis symmetry means the governing buckling mode may be flexural-torsional rather than pure flexural per AISC 360 Eq. E4-4.
- Connection eccentricity: The centroid is closer to the flange — tension connections must account for the induced bending when the work line differs from the centroidal axis.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Tension Capacity — st7_5x25
Scenario: st7_5x25 used as a bottom chord member in a roof truss. The member carries axial tension only under the governing load combination.
Given:
- st7_5x25: gross area Ag = 7.34 in²
- Steel: Fy = 50 ksi, Fu = 65 ksi
- Connection: bolted through the flange with 4 bolts per line (standard holes)
Step 1 — Gross yield (AISC 360 Eq. D2-1):
φTn_yield = 0.9 × Ag × Fy = 0.9 × 7.34 × 50 = 330 kips
Step 2 — Net section fracture:
For bolted connections, deduct bolt holes from Ag: An = Ag − n × dh × tf
The effective net area Ae = U × An depends on the shear lag factor U per AISC 360 Table D3.1.
Check φTn_fracture = 0.75 × Ae × Fu per AISC 360 Eq. D2-2.
Step 3 — Stem-in-tension note:
For WT/ST sections loaded in axial tension, the eccentricity between the centroid and the connection plane introduces a bending moment that should be considered in the connection design. The stem is more flexible than the flange — verify the weld or bolt group can accommodate the induced prying action.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.