W10X17 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 10.10 | in (256.5 mm) |
| Flange Width (bf) | 4.01 | in (101.9 mm) |
| Flange Thickness (tf) | 0.33 | in |
| Web Thickness (tw) | 0.24 | in |
| Area (A) | 4.99 | in² (32.2 cmÃÂò) |
| Weight | 17 | lb/ft (25 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 81.90 | 3.56 | in⁴ |
| Elastic Section Modulus (S) | 16.20 | 1.78 | in³ |
| Plastic Section Modulus (Z) | 18.70 | 2.80 | in³ |
| Radius of Gyration (r) | 4.05 | 0.84 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 0.16 | in⁴ |
| Warping Constant (Cw) | 85.10 | in⁶ |
| Distance Between Flange Centroids (ho) | 9.77 | in |
| Effective Radius (rts) | 1.04 | in |
Section Profile Summary
A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 81.9 in⁴, the strong-axis stiffness places it in the light beam category for preliminary sizing.
At 10.1" deep, this is a compact section a practical choice for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 935 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 81.9 in⁴ |
| Torsion | St. Venant = GJ/L | J = 0.16 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 4.05 in |
Design Notes
- Compactness: Most W-shapes in ASTM A992 satisfy the compact limits in AISC 360 Table B4.1b for flexure (ÃÂû âÃÂä ÃÂûp). This allows full plastic moment Mp development before local buckling occurs.
- Flange local buckling (FLB): The flange slenderness ratio bf/2tf is compared against ÃÂûpf = 0.38âÃÂÃÂ(E/Fy) âÃÂà9.15 for compact sections.
- Web local buckling (WLB): h/tw is checked against ÃÂûpw = 3.76âÃÂÃÂ(E/Fy) âÃÂà90.5 for flexure, and a more restrictive limit for uniform compression.
- Lateral-torsional buckling (LTB): Lp âÃÂà35.6 in (plastic limit). For unbraced lengths âÃÂä Lp, the full plastic moment is available. Between Lp and Lr, linear interpolation per AISC 360 Eq. F2-2 applies.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Parking garage beam — w10x17
Scenario: Parking structure floor beam — asphalt topping included in dead load. Simply supported wide flange, 19 ft span, 9 ft tributary width. Service loads: 80 psf dead + 50 psf live (1170 plf total).
Given:
- Span L = 19 ft (228 in)
- Total service load w = 1170 plf
- Live load portion w_L = 450 plf
- Section w10x17: Ix = 81.9 in⁴, Sx = 16.2 in³, Zx = 18.7 in³
- Steel: ASTM A992, Fy = 50 ksi, E = 29,000 ksi
- Design moment strength: φMn = 0.9 × Zx × Fy = 70 kip-ft
Step 1 — Live load deflection check:
Δ_LL = 5 w_L LâÃÂô / (384 E Ix)
Δ_LL = 5 × (450/12) × (228)âÃÂô / (384 × 29,000,000 × 81.9)
Δ_LL = 0.56 in
Step 2 — Allowable deflection (IBC Table 1604.3, L/240):
Δ_allow = L / 240 = 228 / 240 = 0.95 in
Step 3 — Dead + live deflection:
Δ_total = 1.44 in
Step 4 — Design check:
âÃÂàLive load deflection is within the L/240 limit.
The required flexural strength at ultimate is approximately w_u LÃÂò/8. With factored loads 1.2D + 1.6L, verify φMn = 70 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.